The Solis S6-EH1P8K-L-Plus is the sixth generation single phase hybrid inverter for modern homes. It supports high current PV modules with dual 32A MPPTs and accepts up to 16 kW of solar, giving you room to expand. Installers will appreciate the quick access push in terminals that speed up wiring and remove the need for special plugs. In backup mode it switches in under 4 ms and can deliver 200 percent surge for 10 seconds to start tough loads. With generator compatibility, parallel operation up to 48 kW, IP66 weather protection and smart timed charge and discharge, it offers reliable, flexible energy control for UK and EU households.
Fast installation, strong backup performance, flexible system growth and robust protection. We are an official Solis distributor for the UK and Europe. Next day delivery in the UK and 2 to 3 days to most EU locations via DPD, UPS or TNT.
10 seconds of 200 percent overload, multiple inverters can operate together to form a microgrid, generator compatible to extend backup duration during grid power outage, supports dual backup ports for intelligent control of critical and non critical loads, automatic switchover time is less than 4 ms for seamless transitions, excellent power supply stability even with a weak grid or generator fluctuations.
| Parameter | Value |
|---|---|
| Model | S6-EH1P8K-L-PLUS |
| Recommended max PV power | 16 kW |
| Rated DC voltage | 330 V |
| MPPT voltage range | 90 to 550 V |
| Max short circuit current | 40 A / 40 A |
| Max input strings | 2 |
| Max input voltage | 600 V |
| Start up voltage | 120 V |
| Max input current | 32 A / 32 A |
| Number of MPPTs | 2 |
| Rated AC output power | 8 kW |
| Max AC output power | 8 kVA |
| Rated grid frequency | 50 Hz / 60 Hz |
| Max output current | 36.4 A |
| THDi | less than 3% |
| Max apparent output power | 8 kVA |
| Rated grid voltage | 1/N/PE, 220 V / 230 V |
| Rated grid output current | 36.4 A / 34.8 A |
| Power factor | greater than 0.99 (0.8 leading to 0.8 lagging) |
| Max efficiency | 96.2% |
| EU efficiency | 96.1% |
| DC reverse polarity protection | Yes |
| Output over current protection | Yes |
| Grid monitoring | Yes |
| Temperature protection | Yes |
| Integrated DC switch | Optional |
| Short circuit protection | Yes |
| Surge protection | Yes |
| Anti islanding protection | Yes |
| Integrated AFCI (DC arc fault) | Yes, activation required |
| Dimensions W x H x D | 335 x 560 x 227 mm |
| Weight | 22.2 kg |
| Topology | Transformerless |
| Self consumption at night | less than 1 W |
| Operating temperature | -25 to +60 °C |
| Relative humidity | 0 to 100% |
| Ingress protection | IP66 |
| Cooling | Natural convection |
| Max operating altitude | 4000 m |
| Safety and EMC | IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3 |
| Grid standards | G98 or G99, VDE-AR-N 4105, EN 50549-1, VDE 0126, UTE C 15, VFR:2019, RD 1699, RD 244, UNE 206006, UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA |
| DC connection | MC4 connector |
| AC connection | Quick connection plug |
| Display | LCD |
| Communication | RS485, optional Wi-Fi or GPRS |