Power Quality Meter Analyzer with AC Current True RMS 10A~6000A CT Size Ф300mm
Introduction of Power quality analyzer:
Introduction of Clamp Current Sensor:
Power supply | Rechargeable lithium-ion battery packs 9.6V, backup charger |
Battery indicator |
|
Power consumption | Current consumption of normal test 490 mA, continuous working for 10 hours |
Display mode | LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm |
Size of clamp | Flexible Coil Current Sensor (with Integrator) : Ф300mm |
Instrument dimensions | L×W×H: 277.2mm ×227.5mm ×153mm |
Number of channels | 4U/4I |
Phase-to phase voltage | 1.0V~2000V |
Phase-to-neutral voltage | 1.0V~1000V |
Current | Flexible Coil Current Sensor (with Integrator) : 10A ~ 6000A |
Frequency | 40Hz~70Hz |
Parameters of electricity | W, VA, Var, PF, DPF, cosφ, tanφ |
Energy parameters | Wh, Varh, Vah |
Harmonic | Order 0~50 |
Total harmonic distortion | Order 0~50, each phase |
Expert mode | Yes |
Number of Transient records | 150 sets |
Voltage flicker | Yes |
Starting current mode | Yes, 100 seconds |
3 phases unbalance | Yes |
Record | 300 days(simultaneous recording 20 parameters, record one point every 5 seconds) |
Min/Max recorded value | Measurement of maximum and minimum values over a period of time |
Alarm | 40 different types of parameter selections, 12,800 sets alarm logs |
Peak | Yes |
Phasor diagram display | Automatically |
Capacity of snapshots | 60 |
Menu language | English/Chinese |
Communication | USB |
Automatic switching off | When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off |
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute | |
Backlight function | Yes, suitable for use at night and dark place |
Weight | Host: 1.6kg (with battery) |
circle current clamp: 252g×4 | |
Test wires and power adapter: 800g | |
Total weight: about 10.8kg (with packaging) | |
Length of voltage test wire | 3m |
Length of current sensor wire | 2m |
Working temperature and humidity | -10°C~40°C; below 80%Rh |
Storage temperature and humidity | -10°C~60°C; below 70%Rh |
Input impedance | Input impedance of test voltage: 1MΩ |
Withstand voltage | Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell |
Insulation | Between instrument wiring and shell ≥10MΩ |
Structure | Double insulation, with insulation vibration-proof sheath |
Safely rules | IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2 |