IMPORTANT INSTALLATION NOTE FOR CRUISAIR® MARINE CUSTOMERS ONLY: When installing EasyStart into 220-240V SMX A-288/282/281 control applications that use the triac to switch power to the compressor, it is necessary to replace the triac with a relay. If the triac is not replaced, the EasyStart and any pump relay triggers may suffer damage and ultimately fail. A replacement relay specifically designed for this application is available (ASY-503-X2D). Please note that this is not required for 115V SMX applications, and the triac is still safe to use.

For the bluetooth model please see MICRO-AIR ASY-364-X36-BLUE Easy Start 364 Soft Starter with Bluetooth | eBay