Specification

Product introduction

YWKT-1B input liquid level transmitter is composed of a fully sealed isolation film oil-filled core body and a special circuit for instrument. The product adopts a unique sealing structure with good anti-leakage performance and can work reliably in liquid for a long time. The product has the advantages of high precision, good stability, long life and easy installation. Widely used in water plant, oil refinery, chemical plant, glass plant, sewage treatment plant, high-rise water supply system, reservoir, river, ocean and other water supply pond, distribution pond, water treatment pond, well, water tank, water tank, oil well, oil tank, oil pool and static and dynamic liquid level measurement and control. There is no need to adjust the integrated liquid level products, which can guarantee long-term stability.
item
value
Warranty
1 years

Place of Origin
Shaanxi, China

Model Number
YWKT-1B
precision
0.5% 0.25%
The output signal
4-20mA 0-5V 0-10V 1-10V
The power supply voltage
12-36VDC
The environment temperature
-20-85℃
Measuring range
0-0.5 ~200mH2O
Protection grade
IP67
Working Temperature:
0-65℃

Product features

●316L stainless steel isolation diaphragm structure ● High precision, all stainless steel structure ● Strong anti-interference, good long-term stability ● Gas cable transmission ● Anti-condensation, anti-lightning design ● This security explosion

Installation of liquid level transmitter

1. The transmitter shall be installed according to different use requirements. There are two types of input type and threaded connection type. 2. The input liquid level transmitter can be used in static liquid and moving liquid respectively. The fixed device should be installed in the moving liquid. 3. Threaded connection type is used to measure the liquid level in the container or pipeline system of high-rise building and the liquid level of high temperature and corrosive liquid. 4, in the measurement of high temperature media, should use pressure or cooling devices, in order to reduce the temperature to the transmitter normal use temperature range. 5. Shielded cable can be used in the case of large on-site interference and high user requirements. 6. It is strictly prohibited for the ventilation cable to be flooded or blocked. Note that the cable section above ground needs to be protected. 7. If there is sediment in the measured liquid, the transmitter should be properly raised or filtered to prevent the sediment from blocking the water guide hole. 8. Intrinsically safe and explosion-proof products must be used together with associated equipment (safety grid) to form intrinsically safe and explosion-proof series (see P? As shown in the original security system diagram of the explosion-proof transmitter).