The Fluke FC Wireless HVAC System lets you work on electrical panels faster, safer, easier with remote current and temperature modules
Connect your FC AC Wireless Current Clamp Module to your test point, and view the results up to 20 meters away on the FC Wireless Digital Multimeter. Plus, you can connect the t3000 FC Wireless K-Type wireless temperature module and view remote temperature measurements.
You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect™ modules as a system for multiple measurements.
From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the Fluke Connect remote modules captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.
Now you can take readings on moving machinery, with only the measurement module in harm’s way.
Key features
The Fluke 3000 FC HVAC System provides measurement of all common electrical parameters
The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting:
- AC and DC voltage measurements to 1000 V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX recording
- CAT III 1000 V, Cat IV 600 V; IP54
The Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting:
- True-RMS AC clamp meter
- Measure up to 400 AAC
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
- Inrush function
With the Fluke t3000 FC Wireless K-Type Temperature Module you can:
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
Fluke 3000 FC Series Wireless Multimeter
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [Number of least significant digits]).
| Detailed Specifications |
| AC Voltage |
| Range ¹ / Resolution |
600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V |
| Accuracy 2 3 4 |
45 Hz to 500 Hz |
1.0% + 3 |
| 500 Hz to 1 kHz |
2.0% + 3 |
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz. |
| DC Voltage, Continuity, Resistance, Diode Test and Capacitance |
| Function |
| mV |
Range / Resolution |
600.0 mV / 0.1 mV |
| Accuracy |
0.09% + 2 |
| V |
Range / Resolution |
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V |
| Accuracy |
0.09% + 2
0.15% + 2 |
| ))) |
Range / Resolution |
600 Ω / 1 Ω |
| Accuracy |
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. |
| Ω |
Range / Resolution |
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ |
| Accuracy |
0.5% + 2
0.5% + 1
1.5% + 3 |
| Diode test |
Range / Resolution |
2.000 V / 0.001 V |
| Accuracy |
1% + 2 |
| µF |
Range / Resolution |
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF |
| Accuracy |
1.2% + 2
10% typical |
| 1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. |
| AC and DC Current |
| Function |
mA AC
(45 Hz to 1 kHz) |
Range 1 / Resolution |
60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA |
| Accuracy |
1.5% + 3 |
| mA DC 2 |
Range 1 / Resolution |
60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA |
| Accuracy |
0.5% + 3 |
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload. |
| Frequency |
| Range / Resolution |
99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz |
| Accuracy 1 |
0.1% + 1 |
| 1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. |
| Input Characteristics |
| Function |
Overload
protection |
Input impedance
(nominal) |
Common mode rejection ratio (1 kΩ unbalance) |
Normal mode rejection |
| |
1100 Vrms |
> 10 MΩ < 100 pF |
> 120 dB at DC, 50 Hz or 60 Hz |
> 60 dB at 50 Hz or 60 Hz |
| |
1100 Vrms |
> 10 MΩ < 100 pF |
> 60 dB, DC to 60 Hz |
> 60 dB at 50 Hz or 60 Hz |
| |
1100 Vrms |
> 10 MΩ < 100 pF |
> 120 dB at DC, 50 Hz or 60 Hz |
> 60 dB at 50 Hz or 60 Hz |
| Open circuit test voltage |
Full scale voltage |
Typical short circuit current |
| To 6 MΩ |
50 MΩ |
Typical short circuit current |
| |
1100 Vrms |
< 2.7 VDC |
< 0.7 VDC |
< 0.9 VDC |
< 350 mA |
| |
1100 Vrms |
< 2.7 VDC |
2.000 VDC |
< 1.1 mA |
| mA Function |
| Overload protection |
Fused, 44/100 A, 1000 V FAST Fuse |
| Overload |
600 mA overload for 2 minutes maximum, 10 minutes rest minimum |
| MIN/MAX Recording Accuracy |
| DC functions |
The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration. |
| AC functions |
The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration. |
| General Specifications |
| Maximum voltage between any terminal and earth ground |
1000 VDC or AC rms |
| Ω fuse protection from A inputs |
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |
| Display (LCD) |
Update rate |
4/sec |
| Volts, amps, ohms |
6000 counts |
| Frequency |
10,000 counts |
| Capacitance |
1,000 counts |
| Battery type |
Three AA Alkaline batteries, NEDA 15A IEC LR6 |
| Battery life |
250 hours minimum |
| RF communications |
2.4 GHZ ISM Band |
| RF communication range |
Open air, unobstructed |
Up to 20 m |
| Obstructed, sheetrock wall |
Up to 6.5 m |
| Obstructed, concrete wall, or steel electrical enclosure |
Up to 3.5 m |
| Temperature |
Operating |
-10°C to 50°C |
| Storage |
-40°C to 60°C |
| Temperature coefficient |
0.1 x (specified accuracy) / °C (< 18°C or > 28°C) |
| Relative humidity |
0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C) |
| Altitude |
Operating |
2,000 m |
| Storage |
12,000 m |
Electromagnetic compatibility
EMI, RFI, EMC, RF |
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008,
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
| Safety compliance |
ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010 |
| Certifications |
CSA, FCC, CE |
| Ingress Protection (IP) rating |
IP54 |
| Pollution Degree |
2 |
| Size (H x W x L) |
4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) |
| Weight |
340 g (12 oz) |
| Warranty |
Three years |
| Not compatible with Fluke CNX test tools |
Fluke a3000 FC Wireless AC Current Clamp Module
| Specifications |
| Range |
0.5 A to 400.0 A |
| Resolution |
0.1 A |
| Accuracy |
400.0 A: 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100 Hz to 500 Hz) |
| Inrush |
Max displayed reading |
999.9A |
| Crest factor (50 Hz / 60 Hz) |
3 at 500 A
2.5 at 600 A
1.42 at 1000 A
add 2% for C.F. > 2 |
| LCD w/ backlight |
3½ digits |
| Log rate/interval |
1 sec minimum/adjustable by PC |
| Battery type |
2 AA, NEDA 15 A, IEC LR6 |
| Battery life |
400 hours |
| Memory |
Record up to 65,000 readings |
| RF communications |
2.4 GHZ ISM Band |
| RF communication range |
Open air, unobstructed |
Up to 20 m |
| Obstructed, sheetrock wall |
Up to 6.5 m |
| Obstructed, concrete wall or steel electrical enclosure |
Up to 3.5 m |
| Operating temperature |
-10°C to +50°C |
| Storage temperature |
-40°C to +60°C |
| Temperature coefficient |
Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) |
| Operating humidity |
90% at 35°C
75% at 40°C
45% at 50°C |
| Altitude |
Operating |
2,000 m |
| Storage |
12,000 m |
| EMC |
EN 61326-1:2006 |
| Safety compliance |
IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2 |
| Safety rating |
CAT III 600 V |
| Certifications |
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
| Ingress Protection (IP) rating |
IP30 |
| Pollution Degree |
2 |
| Jaw opening |
34 mm (1.33 in) |
| Size (H x W x D) |
20.3 x 7.49 x 3.55 cm (8 x 2.95 x 1.4 in) |
| Weight |
.22 kg (8 oz) |
| Warranty |
Three years |
| Not compatible with Fluke CNX test tools |
Fluke t3000 FC Wireless K-Type Temperature Module
| General Specifications |
| Range K-Type |
-200°C to 1372°C |
| Resolution |
0.1°C |
| Accuracy |
±[0.5% + 0.3°C] counts |
| Input terminals |
K-type mini |
| LCD w/backlight |
3 ½ digits |
| Log rate/interval |
1 sec minimum/adjustable by PC |
| Battery type |
2 AA, NEDA 15 A, IEC LR6 |
| Battery life |
400 hours |
| Memory |
Record up to 65,000 readings |
| RF communications |
2.4 GHZ ISM Band |
| RF communication range |
Open air, unobstructed |
Up to 20 m |
| Obstructed, sheetrock wall |
Up to 6.5 m |
| Obstructed, concrete wall or steel electrical enclosure |
Up to 3.5 m |
| Operating temperature |
-10°C to +50°C |
| Storage temperature |
-40°C to +60°C |
| Temperature coefficient |
0.01% of reading +0.03°C per°C |
| Temperature scale |
ITS-90 |
| Operating humidity |
90% at 35°C, 75% at 40°C, 45% at 50°C |
| Altitude |
Operating |
2,000 m |
| Storage |
12,000 m |
| EMC |
EN 61326-1:2006 |
| Safety compliance |
IEC 61010-1, CAT I, 3rd edition Pollution Degree 2 |
| Certifications |
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
| Ingress Protection (IP) rating |
IP42 |
| Pollution Degree |
2 |
| Size (H x W x D) |
16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) |
| Weight |
.22 kg (8 oz) |
| Warranty |
Three years |
| Not compatible with Fluke CNX test tools |
Includes:
- Fluke 3000 FC Series Wireless Multimeter
- Fluke a3000 FC Wireless AC Current Clamp Module
- Fluke t3000 Thermocouple Thermometer
- TL175 Test Leads
- AC175 Alligator Clips
- 80PK-1 K-Type Bead Thermocouple
- Magnetic hanging strap
|
| Condition: |
BRAND NEW |
Auction Details:
| Shipping: |
- All domestic packages will be shipped out via Fedex, UPS, or USPS within the lower 48 states
- Shipping to Hawaii Alaska Puerto Rico would be extra, and those shipments will be shipped out via USPS priority mail, unless otherwise stated in the auction or negotiated in emails.
- Shipping to APO, RR, or PO box will be handled via USPS and would be extra on certain items, please email us prior bidding.
- Goods will be dispatched the latest in 2 business days.
- Goods will be shipped out after the holidays and weekends.
- No local pick ups accepted at this time, unless otherwise stated in the auction
- Shipping costs are set at that price to cover some of our costs and packaging and handling fees as well as some of the ebay and paypal fees which add to about 13% of the total end price. Please don't email us to negotiate about the shipping costs. We are extremely busy, so we might not answer your emails.
- Shipping and handling fees are not negotiable, by bidding on this item the buyer agrees to pay for all the shipping costs
- We ship to any destination in the world.
- INTERNATIONAL BUYERS: The International shipping rate is flat rate to most destinations in the world, please email us for additional information.
- California buyers are subject to pay 9% tax.
- International buyers are responsible for all tax and custom duty charges outside the country.
|
| Payment: |
-
U.S. Buyers: Credit cards through PayPal
-
Please note that we can't accept direct credit card payments at this time
-
International Buyers: PayPal or Wire
-
Payment is due within 6 days of auction closing. If payment is not received within this time unless otherwise stated or negotiated, item will be relisted on eBay. |
| Terms & Conditions: |
- After the auction is closed, auction winners should contact us regarding any questions or requests.
- After the auction is closed, payment should be received within 6 days.
- Buyer has 30 days to return the product, return product should be brand new with all original accessories, buyer pays shipping costs both ways.
- Shipping and handling charges are not returnable
- Items will be replaced or exchanged in case of DOA
- If the same item or similar item is not in stock in case of DOA, the buyer will receive a refund back
- We combine shipping to save customers money, however, there will be an additional charge per item, please read the description for each item to find out about the specific fees.
- All buyers are subject to pay all taxes and duty fees inside and outside of the United States,
- Our facilities are closed during the weekends and other holidays and there will be no shipments during these time periods. All packages will go out after the weekend or after the holidays.
|
| Contact Information: |
Please use ebay messaging system |
|