Features:
100MHz bandwidth.
1GS/s sample rate.
Time base range: 2ns/div~100s/div.
3.5ns rise time.
2 channels.
7.0-inch high resolution LCD display.
Support for SCPI and LabVIEW.

Specifications:
Functions & Specifications of SDS1102
Bandwidth100MHz
Sample Rate1GS/s
Horizontal Scale(s/div)2ns/div - 100s/div, step by 1-2-5
Rise Time (at input, typical)≤3.5ns
Channel2
Display7" color LCD, 800 × 480 pixels
Input Impedance1MΩ ± 2%, in parallel with 20pF ± 5pF
Channel Isolation50Hz:100:1, 10MHz:40:1
Max Input Voltage400V (PK-PK) (DC+AC, PK-PK)
DC Gain Accuracy±3%
Record Length10k
DC Accuracy (average)Average≥16: ±(3% reading+0.05div) for △V
Probe Attenuation Factor1X, 10X, 100X, 1000X
LF Respond (AC, -3dB)≥10Hz (at input, AC coupling, -3dB)
Sample Rate / Relay Time Accuracy±100ppm
Interpolationsin (x) / x
Interval(△T) Accuracy (full bandwidth)

Single: ±(1 interval time + 100ppm × reading + 0.6ns),

Average>16: ±(1 interval time + 100ppm × reading + 0.4ns)

Input CouplingDC, AC, and GND
Vertical Resolution (A/D)8 bits (2 channels simultaneously )
Vertical Sensitivity5mV/div - 5V/div (at input)
Trigger TypeEdge, Video
Trigger ModeAuto, Normal, and Single
Trigger Level±5 divisions from screen center
Line / Field Frequency (video)NTSC, PAL and SECAM standard
Cursor Measurement△V, and △T between cursors
Automatic MeasurementVpp, Vavg, RMS, Frequency ,Period, Vmax, Vmin, Vtop, Vbase, Width, Overshoot,
Pre-shoot, Rise time, Fall time, +Width, -Width, +Duty, -Duty, Delay A→B , Delay A→B
Waveform Math+, -, ×, ÷, invert, FFT
Waveform Storage16 waveforms
Lissajous Figure Bandwidthfull bandwidth
Lissajous Figure Phase Difference±3 degrees
Communication InterfaceUSB host, USB device
Frequency Counteravailable
Power Consumption<15W
Fuse2A, T class, 250V
Power Supply220V (EU/UK plug), 110V (US plug), 50/60Hz, CAT II
Plug TypeEU / UK / US (Optional)
Item Size300 * 76 * 153mm / 11.81 * 2.99 * 6.02in
Net Weight1403g / 3.09lb
Package Weight1601g / 3.53lb
Package Size37 * 18 * 11.5cm / 14.57 * 7.09 * 4.53in


Package List:
1 * Oscilloscope
2 * Oscilloscope Probe
1 * Oscilloscope Powerline
1 * Data CD
1 * USB Cable
1 * Package of Accessory
1 * Quick Guide (English)

Time base range: 2ns/div~100s/div. 7.0-inch high resolution LCD display. Functions & Specifications of SDS1102 2ns/div - 100s/div, step by 1-2-5 1MΩ ± 2%, in parallel with 20pF ± 5pF Average≥16: ±(3% reading+0.05div) for △V ≥10Hz (at input, AC coupling, -3dB) Sample Rate / Relay Time Accuracy Interval(△T) Accuracy (full bandwidth) Single: ±(1 interval time + 100ppm × reading + 0.6ns), Average>16: ±(1 interval time + 100ppm × reading + 0.4ns) 8 bits (2 channels simultaneously ) Vpp, Vavg, RMS, Frequency ,Period, Vmax, Vmin, Vtop, Vbase, Width, Overshoot, Pre-shoot, Rise time, Fall time, +Width, -Width, +Duty, -Duty, Delay A→B , Delay A→B Lissajous Figure Phase Difference 220V (EU/UK plug), 110V (US plug), 50/60Hz, CAT II 300 * 76 * 153mm / 11.81 * 2.99 * 6.02in 37 * 18 * 11.5cm / 14.57 * 7.