Low Voltage CT Turn Transformation Ratio Tester Leakage Current Meter Tester
Introduction:
ETCR9600 Low Voltage Transducer Transformation Ratio Tester widely used in 380/220v power system, this instrument is composed of the host machine, primary current clamp CT1 and secondary current clamp CT2, which can conveniently and quickly realize online on-site inspection of the current transducer in the metering device, and the measuring of the current and leakage current magnitude in the 380/220v power system, relized to accurate testing the current transducer transformer ratio, angle difference, phase and polarity in actual operation without power failure.
Function
1. Online test the leakage current, current, transformation ratio, ratio error, angle error, phase and polarity of the primary and secondary circuit of the current transformer in the 380V/220V distribution system
2. Transformation Ratio Measurement Range: 1~500
3. Transformation Ratio Resolution : 0.1
4. Primary Current Clamp Test Accuracy : Range:0.0A~800A;Resolution:0.1A; Accuracy:±0.5%FS((23℃±3℃,below 70%RH,the detected conductor is in the center position of the clamp);
5. Secondary Current Clamp Test Accuracy : Range:0.00mA~5A;Resolution:0.01mA;Accuracy:±0.5%FS
6. Primary Current Clamp Size : 80mm×80mm
7. Secondary Current Clamp Size :φ8mm
Technical Parameter
Function | Current, transformation ratio, ratio error, angle error test, phase and polarity adjustment of the low voltage primary and secondary circuit of the current transducer |
Primary Current Clamp Test Accuracy | Range: 0.0A~800A;Resolution:0.1A; Accuracy:±0.5%FS( 23℃±3℃,below 70% RH,the detected conductor is in the center position of the clamp); |
Secondary Current Clamp Test Accuracy | Range:0.00mA~5A;Resolution:0.01mA;Accuracy:±0.5%FS |
Transformation Ratio Measurement Range | 1~500 |
Transformation Ratio Resolution | 0.1 |
Angle Error Test Accuracy | Range:0~360°;Accuracy:±3° |
Automatic Shut Down | 15 minutes after boot up, the meter shuts down automatically without any operation |
Battery Specification | Alkaline batteries (1.5V AAA × 4) (NOT INCLUDED) |
Battery Voltage | When battery voltage is lower than 4.8V, low battery voltage symbol will display and remind to replace battery. |
Overflow Display | Exceed measure range overflow function: “OLA” symbol display |
Sampling Rate | 3 times/second |
Data Storage | 3000 groups |
Primary Current Clamp Size | Jaw Size:φ80mm×80mm; Out Shape Size: 76mm×255mm×31mm |
Secondary Current Clamp Size | Jaw Size: φ8mm; Out Shape Size: 137mm×40mm×19.5mm |
Host Dimension | 75mm×170mm×30mm |
Current Clamp Cable Length | 2M |
Instrument Weight | 1000g |
Insulation Strength | AC3700V/rms between the core and shell |
Packing :
Host | 1 PCS |
Primary Current Clamp | 1 PCS |
Secondary Current Clamp | 1 PCS |
Tool bag | 1 PCS |
Manual | 1 PCS |
Certificate | 1 PCS |
Warranty Card | 1 PCS |