Ground Earth Resistance Tester Meter 0.01-1200Ω Leakage Current Tester 0.mA~20A 


Note: Battery cannot be included during the shipping !!!


Introduction:

 

1. Clamp Earth Resistance Tester is our company's technology research and development team on technical quality of the pursuit of excellence, through continuous innovation to improve, upgrade with the old product. Its performance is mainly reflected in:

2. Clamp Earth Resistance Tester is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment. In the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use. The tester can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the ETCR series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance.




Function:

1. Measurement of earth resistance, loop resistance

2. Resistance Measure Range: 0.010Ω~1200Ω

3. Leakage Current Measure Range: 0.00mA~20.0A

4. Alarm Threshold Setting1-199Ω

5. Alarm Function: audible and visible alarm

6. CT Size: 65mmX32mm


Specification:

 

Power Supply

6VDC 4 PCS of LR6 lkaline batteries (not included)

Clamp Size

65mm×32mm

LCD Size

4 Digits LCD display, Screen: 47mm×28.5mm

Range

Resistance: 0.010Ω~1200Ω

Current: 0.00mA~20.0A

Resolution

Resistance: 0.001Ω; Current: 0.05mA

Accuracy

Resistance: ±1%±0.01Ω; Current:±2.5%±1mA

Data Storage

99 sets

Data Upload Function

RS232 Interface (Optional)

Auto Power-off

Automatically power off after 5 minutes without any operate

Power Consumption

≤50mAcontinuously working for 30 hours

Working Environment

-20~55℃;20%rh~80%rh

Store Environment

-20~60℃;below 90%rh

Alarm Threshold Setting Range

 Resistance1~199Ω

Audible and VisibleAlarm

 “Beep-beep-beepalarm sound, alarm symbol flashing, pressALkey to turn  on/off and setting

Interference Signal Recognition

Beep-beep-beepindicator,NOISEsymbol blinking

Protection Level

Double insulation

Structural Feature

Clamp CT

Shift

Automatic shift

External Magnetic Field

40A/m

External Electrical Field

1V/m

Single Measurement Time

0.5 second

Resistance Measurement Frequency

1KHz

Measured Current Frequency

50/60Hz Automatic

Low Battery Voltage Indication

When the battery voltage is lower than 5.3V, the low battery voltage symbol is displayed

Storage Full Indication

Storage data full of 99 sets,flashed display "MEM" symbol

Over Range Indication

Over range indication OLΩ”, L0.01or OL A

Tester Weight

1160g 

Tester Dimension

285mm×85mm×56mm



Accessories:


DataCaciques