Multi-Parameter Monitor
| Brand | Yongrow |
| Fuse | F2AL 250V |

Electrical Specifications:

Voltage/Frequency: 220 VAC, 50Hz

Environmental Conditions:

Operating Temperature: 5°C to 40°C

Working Humidity: 15% to 80% (non-condensing)

Atmospheric Pressure: 86 kPa to 106 kPa

Power & Battery:

Maximum Input Power: 70VA

Battery: 11.1V 2200mAh rechargeable lithium battery

Physical Dimensions:

Weight: 4.5 kg

Product Size: 342 × 252 × 139.5 mm (L × W × H)

Detection Functions
Protect the health of the elderly

ECG
Five-lead ECG monitoring, with simultaneous display of seven-lead waveforms on the same screen.

NIBP
One-button blood pressure measurement, includes a blood pressure list, and features dual software and hardware overvoltage protection.

TEMP
Contact-based body temperature measurement, allows synchronous comparison of multiple parameters, and provides body temperature trend statistics.

RESP
Uses thoracic impedance method to extract respiratory waves, displaying both respiratory waveform and respiratory rate on the same screen.

SPO2/PR
Utilizes LFC optical frequency digital conversion technology, displays blood oxygen saturation and pulse rate in large font, and synchronously shows the pulse oximetry diagram.

Kind Tips

The Importance of Having a Monitor at Home
With the improvement of living standards, there is a growing demand for daily health care. Traditional devices like blood pressure monitors, oximeters, and ECG detectors can no longer meet higher healthcare needs due to their functional limitations. At the same time, with the popularization of medical equipment, for individuals who are bedridden or suffer from chronic diseases, a comprehensive monitor that tracks vital signs—such as blood pressure, ECG, blood oxygen, pulse rate, respiration, and body temperature—is essential to safeguard health and minimize bodily damage caused by illnesses.

SpO2
SpO2 represents the percentage of oxygen-bound hemoglobin (HbO2) in the blood relative to total hemoglobin (Hb). It reflects whether the body is experiencing hypoxia and is a crucial physiological parameter in the respiratory cycle.

Healthy individuals: SpO2 ≥ 94%

Insufficient oxygen supply: SpO2 < 94%

Hypoxemia: SpO2 < 90%

RESP (Respiration)
The monitor measures respiration using the thoracic impedance method. During breathing, chest movements cause changes in impedance between the electrodes, allowing extraction of respiratory rate (breaths per minute).

Adults: 12–20 breaths/min

Newborns: 30–50 breaths/min (decreases with age)

Vital Signs
Vital signs—respiration, body temperature, pulse, and blood pressure—are fundamental to sustaining normal bodily functions. Any abnormality in these signs can lead to severe or fatal conditions, making them critical indicators of overall health.

ECG (Electrocardiogram)
An ECG records the electrical activity of the heart as it cycles through excitation from the pacemaker, atria, and ventricles. These bioelectric changes are captured via electrodes and displayed as waveforms.

Monitoring Types:

Heart rate (rhythm)

Heart rate (rate)

NIBP (Non-Invasive Blood Pressure)
Blood pressure reflects hemodynamic status, with systolic (peak pressure) and diastolic (resting pressure) values indicating cardiac cycle changes.

Measurement Method: Intelligent oscillometric technique

Parameters: Systolic BP, diastolic BP, mean arterial pressure, pulse rate

Modes: Manual, automatic, continuous

TEMP (Temperature)
The monitor uses a negative temperature coefficient (NTC) thermistor for temperature sensing, where resistance changes correlate with temperature.

Probe Types:

Surface probe (skin temperature)

Cavity probe (internal temperature)