If you need to purchase other configurations besides the standard configuration, please contact the seller before making a purchase.

TECHNICAL SPECIFICATIONS
Multi-parameter Patient Monitor
Quality Standards and Classification
· CE,ISO13485

· SFDA Class IIlb

· Anti-electroshock degree: ClassII

· Grade:ipx7

· TEM/SPO2/NIBP-BF

· ECG/RESP: CF

Application Range
· Adult/Pediatric/Neonatal/Medicine

· Surgery/Operating Room/ICU/CCU

Display
· 15" real color TFT screen

· Resolution:1024*768

· One alarm indicator(Yellow/Red)

· One working indicator(green)

· One battery charge

· Three modes in accordance with the alarm state

Environment
Operating Environment
· Temperature:0 - 40°C

· Humidity:≤85%

· Altitude:-500-4600m

Transport and Storage Environment
· Temperature:-20-60°C

· Humidity:≤5%

· Altitude:-500-1300m

Power Requirements
· AC:100 - 240V,50Hz/60Hz

· DC:Built-in rechargeable battery

· Battery life:500min at ICU mode(4 hours operating after full charge one piece)

· 4 hours operating after full charge(one piece)

· 5min operating after low battery alarm

Dimension and Weight
Equipment
· 300mm288mm155mm(about);

· Weight:about

Package
· 350mm380mm300mm(about);

· 6.5kg(about)

Data Storage
· Trend diagram/table:7*24h

· NIBP review:400 items

· Wave review:100 items

· Alarm review:100 alarm events

· Support drug concentration trend analysis

ST Segment
· ST Segment Range:-2.0mV - +2.0mV

· Accuracy:0.02mV

Pulse Rate
· Range:20 - 300bpm

· Resolution:1bpm

· Precision:±3bpm

ECG
· 5 Leads: RA,LA,LL,RL,V

· Lead mode: III,III,aVR,aVL,aVF

· Input range:-2500, -5000, ×1000

· Sensitivity:>200u (Peak-to-peak value)

· Input impedance:>5 m(ohm)

· Bandwidth:Suction 0.5 - 150Hz

· Monitor:0.5 - 40Hz

· Diagnosis:0.05 - 130Hz

· Polarization Voltage:300mV

· Baseline Recovery Time:After defibrillation 3 seconds

· Signal Range:8mV (Peak-to-peak)

· Calibrating Signal:1mV, precision ±5%

SpO2
· Range:0 - 100%

· Resolution:1%

· Precision:70% - 100% ±2 DIGIT

· 0% - 69%:no definition given

TEMP
· Channel:2

· Measure & alarm range:0 - 50°C

· Resolution:0.1°C

· Precision:±0.1°C

RESP
· Method:RA-LL Impedance

· Resp impedance range:0.3 - 3

· Base impedance range:200 - 4000

· Bandwidth:0.1 - 2.5Hz

· Resp rate:Adult 0 - 120BPM

· Neonatal/Pediatric:0 - 150BPM

· Breath pause alarm:>60 sec

· Asphyxia Alarm:10 - 40 seconds

NIBP
· Method:Pulse wave oscillometry

· Work mode:Manual/Auto/STAT

· Measuring time:STAT mode<60 sec,1,2,3,4,5,6,10,15,30,60,90,120,240,480 minutes(24h)

· Measuring Time of STAT MODE:<5 sec

· PR range:30 - 250bpm

· Measure & accuracy range:

o Adult: SYS 40 - 270mmHg

o DIA 10 - 215mmHg

o MEAN 20 - 235mmHg

o Pediatric: SYS 40 - 250mmHg

o DIA 10 - 165mmHg

o MEAN 20 - 185mmHg

o Neonatal: SYS 40 - 150mmHg

o DIA 10 - 110mmHg

o MEAN 20 - 110mmHg

· Static pressure range:0 - 300mmHg

· Precision:±3mmHg

· Pressure precision:

o Max average error:±5mmHg

o Max standard deviation:±8mmHg

· Overpressure protection:

o Adult:240mmHg

o Pediatric:240mmHg

o Neonatal:150mmHg

· Heart rate range:15 - 380bpm

· Heart rate accuracy:±1 - 1%

CO2 (Optional)
· Side/Main stream

· Warm-up time:when the ambient temperature is 25°C, the carbon dioxide concentration is 5%, the warm-up time is 20/15 seconds, and all the specifications can be fulfilled within 2 minutes.

· Measurement range:0 - 150mmHg0 - 19.7kPa - 0.20kPa (at 760mmHg)0 - 150mmHg

· Accuracy:±2% or ±1mmHg, which great

· Resolution:0 - 1mmHg

· Sensitivity:5uV/mmHg

· Impedance:300 - 3000

· Resolution:1mmHg

· Accuracy:±2% or ±1mmHg (reading)

· Actualization interval:about 1 Sec

Standard Accessories
· NIBP cuff & tube

· ECG cable & electrodes

· SpO2 sensor

· TEMP probe

· Lithium-ion battery

· Power cable

· Operator's manual

Optional
· EtCO2

· CO2 module

· IBP module

· Touch screen

· Hanging bracket

· Monitor recorder