TECHNICAL SPECIFICATIONS
Multi-parameter Patient Monitor
Quality Standards and Classification
· CE,ISO13485
· SFDA Class IIlb
· Anti-electroshock degree: ClassII
· Grade:ipx7
· TEM/SPO2/NIBP-BF
· ECG/RESP: CF
Application Range
· Adult/Pediatric/Neonatal/Medicine
· Surgery/Operating Room/ICU/CCU
Display
· 15" real color TFT screen
· Resolution:1024*768
· One alarm indicator(Yellow/Red)
· One working indicator(green)
· One battery charge
· Three modes in accordance with the alarm state
Environment
Operating Environment
· Temperature:0 - 40°C
· Humidity:≤85%
· Altitude:-500-4600m
Transport and Storage Environment
· Temperature:-20-60°C
· Humidity:≤5%
· Altitude:-500-1300m
Power Requirements
· AC:100 - 240V,50Hz/60Hz
· DC:Built-in rechargeable battery
· Battery life:500min at ICU mode(4 hours operating after full charge one piece)
· 4 hours operating after full charge(one piece)
· 5min operating after low battery alarm
Dimension and Weight
Equipment
· 300mm288mm155mm(about);
· Weight:about
Package
· 350mm380mm300mm(about);
· 6.5kg(about)
Data Storage
· Trend diagram/table:7*24h
· NIBP review:400 items
· Wave review:100 items
· Alarm review:100 alarm events
· Support drug concentration trend analysis
ST Segment
· ST Segment Range:-2.0mV - +2.0mV
· Accuracy:0.02mV
Pulse Rate
· Range:20 - 300bpm
· Resolution:1bpm
· Precision:±3bpm
ECG
· 5 Leads: RA,LA,LL,RL,V
· Lead mode: III,III,aVR,aVL,aVF
· Input range:-2500, -5000, ×1000
· Sensitivity:>200u (Peak-to-peak value)
· Input impedance:>5 m(ohm)
· Bandwidth:Suction 0.5 - 150Hz
· Monitor:0.5 - 40Hz
· Diagnosis:0.05 - 130Hz
· Polarization Voltage:300mV
· Baseline Recovery Time:After defibrillation 3 seconds
· Signal Range:8mV (Peak-to-peak)
· Calibrating Signal:1mV, precision ±5%
SpO2
· Range:0 - 100%
· Resolution:1%
· Precision:70% - 100% ±2 DIGIT
· 0% - 69%:no definition given
TEMP
· Channel:2
· Measure & alarm range:0 - 50°C
· Resolution:0.1°C
· Precision:±0.1°C
RESP
· Method:RA-LL Impedance
· Resp impedance range:0.3 - 3
· Base impedance range:200 - 4000
· Bandwidth:0.1 - 2.5Hz
· Resp rate:Adult 0 - 120BPM
· Neonatal/Pediatric:0 - 150BPM
· Breath pause alarm:>60 sec
· Asphyxia Alarm:10 - 40 seconds
NIBP
· Method:Pulse wave oscillometry
· Work mode:Manual/Auto/STAT
· Measuring time:STAT mode<60 sec,1,2,3,4,5,6,10,15,30,60,90,120,240,480 minutes(24h)
· Measuring Time of STAT MODE:<5 sec
· PR range:30 - 250bpm
· Measure & accuracy range:
o Adult: SYS 40 - 270mmHg
o DIA 10 - 215mmHg
o MEAN 20 - 235mmHg
o Pediatric: SYS 40 - 250mmHg
o DIA 10 - 165mmHg
o MEAN 20 - 185mmHg
o Neonatal: SYS 40 - 150mmHg
o DIA 10 - 110mmHg
o MEAN 20 - 110mmHg
· Static pressure range:0 - 300mmHg
· Precision:±3mmHg
· Pressure precision:
o Max average error:±5mmHg
o Max standard deviation:±8mmHg
· Overpressure protection:
o Adult:240mmHg
o Pediatric:240mmHg
o Neonatal:150mmHg
· Heart rate range:15 - 380bpm
· Heart rate accuracy:±1 - 1%
CO2 (Optional)
· Side/Main stream
· Warm-up time:when the ambient temperature is 25°C, the carbon dioxide concentration is 5%, the warm-up time is 20/15 seconds, and all the specifications can be fulfilled within 2 minutes.
· Measurement range:0 - 150mmHg0 - 19.7kPa - 0.20kPa (at 760mmHg)0 - 150mmHg
· Accuracy:±2% or ±1mmHg, which great
· Resolution:0 - 1mmHg
· Sensitivity:5uV/mmHg
· Impedance:300 - 3000
· Resolution:1mmHg
· Accuracy:±2% or ±1mmHg (reading)
· Actualization interval:about 1 Sec
Standard Accessories
· NIBP cuff & tube
· ECG cable & electrodes
· SpO2 sensor
· TEMP probe
· Lithium-ion battery
· Power cable
· Operator's manual
Optional
· EtCO2
· CO2 module
· IBP module
· Touch screen
· Hanging bracket
· Monitor recorder