Power Quality Meter Three Phase Power Quality Analyzer Current Clamp 1.0A~1000A
Introduction:
Main Function:
Features:
Specifications:
Power Supply
|
Rechargeable lithium battery 7.4V, external charger
|
Battery Indicator
|
Battery symbol shows power energy. When the voltage is too low, automatic shutdown
|
Working Current
|
About 490 mA
|
Instrument Dimension
|
240mmX170mmX68 mm
|
Display Mode
|
5inch touch colorful screen
|
Current
|
Current clamp: 1.0A~1000A
|
Clamp Current Sensor CT Size
|
Φ50mm
|
Frequency
|
40Hz~70Hz.
|
Harmonic
|
Yes, 2~51 orders
|
Total Harmonic Distortion
|
Yes, 2~51orders, each phase
|
Three-phases Unbalance
|
Yes.
|
Communication Interface
|
USB
|
Language
|
Switch between Chinese and English
|
Automatic Shutdown
|
In recording mode, the instrument will not automatic shutdown
|
When not in recording mode, can set the automatic shoutdown time after 15minutes,30minutes,60minutes according to request
|
|
Automatic Shutdown
|
In the alarm mode/trend chart record mode/transient capture mode (waiting or in progressing), the instrument will not automatic shutdown
|
In other test mode, within 15 minutes without keystrokes operation, automatic shutdown after prompt 1 minute.
|
|
Weight
|
Host: 900g (with battery).
|
Clamp current sensor: 510gX4
|
|
Test lines: 400g;
|
|
Total weight: about 8kg (with all accessories).
|
|
Memory Card
|
4G(expandable up to 32G)
|
Voltage Test Line Length
|
3m
|
Current Sensor Line Length
|
2m
|
Working Temperature
|
-10°C~40°C; below 80%Rh.
|
Storage Temperature
|
-10°C~60°C; below 70%Rh.
|
Input Impedance
|
Input impedance of test voltage: 1MΩ.
|
Withstand Voltage
|
Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and housing.
|
Insulation
|
Between instrument wiring and shell ≥10MΩ.
|
Structure
|
Double insulation, with insulation vibration-proof sheath.
|
Suitable Safe Standard
|
IEC 61010 Cat III 1000V /CAT IV 600V , IEC61010-031, IEC61326, Pollution degree 2
|
Measurement
|
Range
|
Display Resolution
|
The Max Error In Reference Range
|
Frequency
|
40Hz~ 70Hz
|
0.001Hz
|
±(0.01)Hz
|
Phase Voltage True RMS
|
2V~ 600V
|
Min resolution 0.001V
|
±(0.5%rdg)
|
Current True RMS
|
10mA~ 6000A
|
Min resolution 0.001A
|
±(0.5%rgt)
|
Active Power
|
0.0000W~ 3600kW
|
Min resolution 0.001W
|
±(1%+3dgt)
Cosφ≥0.8
|
±(1.5%+10dgt)
0.2≤Cosφ<0.8
|
|||
Reactive Power
|
0.000VAR~3600kVAR
|
Min resolution 0.001VAR
|
±(1%+3dgt)
Sinφ≥0.5
|
±(1.5%+10dgt)
0.2≤Sinφ<0.5
|
|||
Apparent Power
|
0.000VA~9999.9kVA |
Min resolution 0.001VA
|
±(1%+3dgt)
|
Power Factor
|
-1.000~ 1.000
|
0.001
|
±(1.5%+3dgt)
Cosφ≥0.5
|
±(1.5%+10dgt)
0.2≤Cosφ<0.5
|
|||
Phase Angle
|
-179°~ 180°
|
0.001°
|
±(2°)
|
Voltage Harmonic Ratio
2-51 orders (Vrms>50V)
|
0.0%~ 99.9%
|
0.001%
|
(2~20orders)±(1%+5dgt)
(21~30orders)±(1%+10dgt)
(31~51orders)±(1%+15dgt)
|
Voltage Harmonic Angled
(Vrms>50V)
|
-179°~ 180°
|
0.001°
|
±(3°) harmonics for 2 - 25 orders
|
±(10°) harmonics for 26 - 50 times
|
|||
Current Harmonic Ratio
2-51 orders
(Arms>Irange/100)
|
0.0%~99.9%
|
0.001%
|
(2~20orders) ±(1%rdg+5dgt)
(21~30orders) ±(1%rdg+10dgt)
(31~51orders) ±(1rdg%+15dgt)
|
Current Harmonic Angle
(Arms>Irange/100)
|
-179°~180°
|
0.001°
|
±(3°) harmonics for 2 - 25 orders
±(10°) harmonics for 26 - 51 orders
|
Total Harmonic Ratio
(THD or THD-F)≤50
|
0.0%~ 99.9%
|
0.001%
|
±(1%rdg+10dgt)
|
Distortion Factor
(DF or THD-R)≤50
|
0.0%~ 99.9%
|
0.001%
|
±(1%rdg+10dgt)
|
Three-phases Unbalance
|
0.0%~ 100%
|
0.01%
|
±(1%)
|
Item
|
Accessories
|
Qty
|
1
|
Host
|
1PCS
|
2
|
Clamp Current Sensor |
4PCS
|
3
|
Pen Probe Test line(Each 1PCS of yellow,green, red and black, length 3m)
|
4PCS
|
4
|
Alligator Clip
|
4PCS
|
5
|
Power Adaptor(DC 12V)
|
1PCS
|
6
|
USB Data Cable
|
1PCS
|
7
|
4G Memory Card
|
1PCS
|
8
|
Manual, Warranty Card, Qualification Card
|
1SET
|