W-200B Urinalysis Urine Medical Equipment Automated Testing urinalysis machine Urine analyzer
Product Parameters.
Detection principle: wavelength visible light wavelength
Test items: urine bile, bilirubin, ketone bodies, creatinine, occult blood, protein, microalbumin, nitrite, white blood cells, glucose, specific gravity, PH, ascorbic acid (VC), calcium ions
Testing speed: 60 times/hour for single-step testing, 120 times/hour for continuous testing
Database capacity: 1000 test report forms (including date, time, ID number)
Display: 240×128
Language: English, Chinese, can be adapted to other languages
Printer: built-in thermal printer, with an external pin printer interface
External output: Standard RS232 output port, can be networked with PC.
Network: wireless network
Use of the environment: 0 ℃ ~ 40 ℃
Test environment: 20 ℃ ~ 25 ℃ RH <85%
Fuse specification: 250 V 2A
Power supply: AC 220V (±15%), 50~60Hz
Power: ≤60W
Net weight: 2.5Kg
Dimension: 455mm×395mm×208mm
Transmission rate: 1200bps, 2400bps, 4800bps, 9600bps, 19200bps, 38400bps, 57600bps
Advantage: It can test 14 items of urine, and the test items and order of the test strips can be customized according to the needs of customers.
Usage Scenario: Applicable departments, township offices, health centers, maternity and child care, medical checkups, clinics, health clinics, schools, home care, health observation, regular medical checkups, etc.
Specification
item
value
Type
Urine Analysis System
Brand Name
Merydi
Model Number
W-200B
Place of Origin
China
Instrument classification
Class II
Warranty
2 years
After-sale Service
Online technical support
Product name
Urine Analyzer
Language
English/Chinese/OEM
Weight
5kg
Test item
10,11,12,13,14 items
Storage
2-30℃
Test Speed
120 tests/Hour
Dimensions
350*320*150mm
Certificate
CE ISO
Usage
Home Clinic Hospital
Accuracy
99.5%
[Storage conditions and shelf life]:
1 . Storage conditions: 2 ℃ ~ 30 ℃ dry place to keep away from light.
2. Product shelf life: 12 months.
3. Shelf life of the opened bottle: after opening, the tube cover needs to be sealed, please use it up as soon as possible (recommended within 90 days).
[Sample Requirements]:
1. Sample volume of 5-10ml, if there is precipitate, need to take the supernatant after resting test.
2. The test is conducted at room temperature around 25℃.
[Test method]:
1. Immerse the reaction area of the test strip into the solution to be tested for 1-2 seconds, remove the test strip and drain off the excess water on it.
2. 120 seconds later, the reaction area of the test strip and the color of the colorimetric card for comparison, so as to determine the test value of the solution to be tested.
3. The colorimetric time should be controlled within 120s, too long or too short time will affect the reading.
[Note]:
1. Do not touch the test paper reaction color block when removing the test paper, so as not to contaminate the test paper and affect the test results.
2. After removing the required number of test strips, seal the remaining test strips and keep them away from light. 3.
3. Try to keep the liquid to be tested colorless or light-colored, the color of the liquid is too dark before the test, can be adsorbed with activated carbon to do dehydration. If the liquid to be tested is turbid, let it sit for a while and take the clear part for testing after precipitation.

On Jun 17, 2025 at 03:51:12 PDT, seller added the following information:


On Nov 20, 2025 at 15:11:22 PST, seller added the following information:

Datacaciques