Parameter


Function Description: 

Forward and Reverse start buttons: K1 / K2 ; Limit Buttons: SW1 / SW2

Self-locking mode:

1- short press K1, the motor starts running forward immediately and stops after SW1 is closed.

2- short press K2, the motor starts running reverse immediately and stops after SW2 is closed.

Inching mode:

1- press and hold K1, the motor starts running forward immediately and stops after SW1 is closed.

2- press and hold K2, the motor starts running forward immediately and stops after SW2 is closed.


Package:
1pcs TKS-M8 DC Motor Driver Module


Frequency Q/A

1. what's the difference between "inching" mode and "self-locking" mode

    self-locking mode: short press the forward switch (k1) , the motor running forward , even you release k1, the motor still running.  it will not stop until encounters a reverse signal (k2)  or (sw2) .

    incing mode: press and hold the forward switch (k1) , the motor running forward,  if release the k1, the motor will stop immediately.

2.  what are the requirements for the signal ?  Can i connect a sensor ?

    signal is vaild at low level  ,  it can be connected to three-wire sensors (NPN-NO type), k1 , k2 , k3 are this type.

3.  Is the limit signal valid in inching mode ?

     valid.  such as when k1 is on , motor will run forward , but the SW1 also have signal ,  it will stop at this time.