switch# show version
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (C) 2002-2023, Cisco and/or its affiliates.
All rights reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under their own
licenses, such as open source. This software is provided "as is," and unless
otherwise stated, there is no warranty, express or implied, including but not
limited to warranties of merchantability and fitness for a particular purpose.
Certain components of this software are licensed under
the GNU General Public License (GPL) version 2.0 or
GNU General Public License (GPL) version 3.0 or the GNU
Lesser General Public License (LGPL) Version 2.1 or
Lesser General Public License (LGPL) Version 2.0.
A copy of each such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://opensource.org/licenses/gpl-3.0.html and
http://www.opensource.org/licenses/lgpl-2.1.php and
http://www.gnu.org/licenses/old-licenses/library.txt.
Software
BIOS: version 5.3.1
NXOS: version 9.3(12)
BIOS compile time: 05/17/2019
NXOS image file is: bootflash:///n3100-compact.9.3.12.bin
NXOS compile time: 6/20/2023 12:00:00 [06/23/2023 17:33:36]
Hardware
cisco Nexus 3172T Chassis
Intel(R) Pentium(R) CPU @ 2.00GHz with 4029684 kB of memory.
Processor Board ID FOC18212WWJ
Device name: switch
bootflash: 1838592 kB
usb1: 0 kB (expansion flash)
Kernel uptime is 0 day(s), 0 hour(s), 3 minute(s), 33 second(s)
Last reset at 914454 usecs after Fri Feb 21 14:13:31 2025
Reason: Kernel Reboot
System version:
Service:
plugin
Core Plugin, Ethernet Plugin
Active Package(s):
switch# show inventory
NAME: "Chassis", DESCR: "Nexus 3172T Chassis"
PID: N3K-C3172TQ-10GT , VID: V01 , SN: FOC1821R0P7
NAME: "Slot 1", DESCR: "48x10GT + 6x40G Supervisor"
PID: N3K-C3172TQ-10GT , VID: V01 , SN: FOC18212WWJ
NAME: "Power Supply 1", DESCR: "Nexus 3172T Chassis Power Supply"
PID: NXA-PAC-500W , VID: V01 , SN: LIT17300JTP
NAME: "Power Supply 2", DESCR: "Nexus 3172T Chassis Power Supply"
PID: NXA-PAC-500W , VID: V02 , SN: DCB2224L0ST
NAME: "Fan 1", DESCR: "Nexus 3172T Chassis Fan Module"
PID: NXA-FAN-30CFM-F , VID: V00 , SN: N/A
NAME: "Fan 2", DESCR: "Nexus 3172T Chassis Fan Module"
PID: NXA-FAN-30CFM-F , VID: V00 , SN: N/A
NAME: "Fan 3", DESCR: "Nexus 3172T Chassis Fan Module"
PID: NXA-FAN-30CFM-F , VID: V00 , SN: N/A
NAME: "Fan 4", DESCR: "Nexus 3172T Chassis Fan Module"
PID: NXA-FAN-30CFM-F , VID: V00 , SN: N/A
switch# show license usage
Feature Ins Lic Status Expiry Date Comments
Count
-------------------------------------------------------------------------------
VPN_FABRIC No - Unused -
NXOS_OE_PKG No - Unused -
24P_N3K_LIC_PKG No - Unused -
48P_N3K_UPG_PKG No - Unused -
TP_SERVICES_PKG No - Unused -
NXOS_ADVANTAGE_XF No - Unused -
NXOS_ESSENTIALS_XF No - Unused -
NETWORK_SERVICES_PKG No - Unused -
LAN_BASE_SERVICES_PKG Yes - Unused never -
LAN_ENTERPRISE_SERVICES_PKG No - Unused -
-------------------------------------------------------------------------------
switch# show environment fan
Fan:
---------------------------------------------------------------------------
Fan Model Hw Direction Status
---------------------------------------------------------------------------
Fan1(sys_fan1) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan2(sys_fan2) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan3(sys_fan3) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan4(sys_fan4) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan_in_PS1 NXA-PAC-500W -- front-to-back Ok
Fan_in_PS2 NXA-PAC-500W -- front-to-back Ok
Fan Zone Speed: Zone 1: 0x28
Fan Air Filter : NotSupported
switch# show environment power
Power Supply:
Voltage: 12 Volts
-----------------------------------------------------------
PS Model Input Power Current Status
Type (Watts) (Amps)
-----------------------------------------------------------
1 NXA-PAC-500W AC 504.00 42.00 ok
2 NXA-PAC-500W AC 504.00 42.00 ok
Mod Model Power Current Power Current Status
Requested Requested Allocated Allocated
(Watts) (Amps) (Watts) (Amps)
--- ---------------------- ------- ---------- --------- ---------- --------
--
1 N3K-C3172TQ-10GT 348.00 29.00 348.00 29.00 pow
ered-up
Power Usage Summary:
--------------------
Power Supply redundancy mode: Redundant
Power Supply redundancy operational mode: Redundant
Total Power Capacity 1008.00 W
Power reserved for Supervisor(s) 348.00 W
Power currently used by Modules 0.00 W
-------------
Total Power Available 660.00 W
-------------
switch# show environment temp
Temperature:
-------------------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
-------------------------------------------------------------------------
1 ASIC 110 100 45 Ok
1 Front-Left (D1) 70 60 25 Ok
1 Front-Right(D2) 70 56 23 Ok
1 Back (D3) 70 46 20 Ok