Electrical data
| Parallel connection | No |
|---|
| Series connection | Yes |
|---|
| Number of devices series connection max. | 2 |
|---|
Electrical data | Supply
| Protective measure | SELV |
|---|
| Power frequency | 50 ... 60 Hz |
|---|
Electrical data | Input
| Input voltage AC min. | 95 V |
|---|
| Input voltage AC max. | 265 V |
|---|
| Nominal input voltage AC | 115 V … 230 V |
|---|
| Input voltage DC min. | 110 V |
|---|
| Input voltage DC max. | 300 V |
|---|
| Nominal current AC | 0.3 A @ 115 V,0.2 A @ 230 V |
|---|
| Inrush current max. | 15 A |
|---|
| Efficiency | 80 % |
|---|
| External back-up fuse per phase max. | 10 A |
|---|
Electrical data | Output
| Output voltage adjustable | Yes |
|---|
| Output voltage DC | 5 V |
|---|
| Output voltage DC min. | 4,2 V |
|---|
| Output voltage DC max. | 6 V |
|---|
| Output current | 3 A |
|---|
| Spikes (s-s) max. | 120 mV |
|---|
| Ripple effective max. | 20 mV |
|---|
Device protection | Electrical
| Overload protection output | Yes |
|---|
| Short-circuit protection output | Yes |
|---|
Mechanical data | Mounting data
| Height | 76 mm |
|---|
| Width | 38 mm |
|---|
| Depth | 87,5 mm |
|---|
| Mounting method | geschnappt |
|---|
| Suitable for mounting type | Mounting rail TH35, (EN 60715) |
|---|
Environmental characteristics | Electromagnetic compatibility
| Interference emission | IEC/EN 55022, IEC 61000-3-2 |
|---|
Environmental characteristics | Climatic
| Operating temperature min. | 0 °C |
|---|
| Operating temperature max. | 50 °C |
|---|
| Derating | 40 °C |
|---|
| Ambient temperature (storage, transport) | -20 °C … 85 °C |
|---|
| Relative humidity (operation) | 5 % … 95 % |
|---|
| Additional condition relative humidity | no condensation |
|---|
Conformity
| Product standard | EN IEC 61010-2-201, EN 61204-3 |
|---|