7 inch Touch screen Multi-parameter patient monitor ECG/RESP/TEMP/NIBP/SPO2/PR M7

Features:
1.7 inch screen with true color, wide viewing angle, high brightness LCD display. 
2.Simple and friendly operating display interface. 
3.Internal chargeable large capacity battery provides convenience for patients' moving. 
4.Playback and browse function for long term waveform and monitor data record. 
5.Auto double alarm with audible and visible signals. 
6.Anti-defibrillation, anti-interference from high frequency electric knife.

Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR

Technique Specifications:
ECG
1.Lead Menuuration: Five lead ( I, II, III, aVR, aVL, aVF, V)
2.Gain: *0.25,0.5,1,2, automatic. Gain change per min was less than 0.66% / min, The total change in gain within 1h was less than ± 10%.
3.Heart rate: measuring range:
①15 to 300 bpm for adults (beat / min)
②Newborn / child 15-350 bpm (beat / min)
③Accuracy: ± 1% or ± 1 bpm, take the large one
4.Heart rate alarm range:
①Upper limit (adult): 17-300 bpm
②Upper limit (neonate / child): 17 to 350 bpm
③Lower limit (adult): 15 ~ 298 bpm
④Lower limit (newborn / child): 15-348 bpm
⑤Resolution: 1 bpm
⑥Alarm limit error: ± 1% or ± 1 bpm, if large
5.ST segment detection and measurement
①Measuring range: -2.0 mV ~ + 2.0 mV
②Measurement accuracy: the measurement error between-0.02

RESP
1.Measurement method: RA-LL impedance method
2.Detection range of respiratory impedance: 0.3~3Ω
3.Baseline impedance range: 200~4000Ω
4.Tape width: 0.1~2.5Hz
5.Respiratory rate range: From 0 to 120 BrPM in adults
6.Children and newborns ranged from 0 to 150 BrPM
7.The measurement error shall be ± 2 BrPM within 7 BrPM to 120 BrPM.

SpO2
1.Measuring range: 0~100%
2.Resolution ratio: 1%
3.Accuracy: Within the range of 70% to 100%, the measurement error
shall be ± 2%; Measurement error is not defined from 0% to 69%

PR
1.measuring range: 25~250bpm
2.Resolution ratio: 1bpm
3.Accuracy: ±3bpm
4Refresh time: 1s

TEMP
1.Applicable temperature sensor: Body chamber probe / body temperature probe
2.Number of channels: 2 channel
3.Measuring range: 0~50℃
(The maximum allowable error of a complete thermometer is ±
0.2℃ from 25℃ to 45℃)
4.Resolution ratio: 0.1℃
5.Alarm accuracy: *0.1℃ (without probe error)

NIBP
1.Measurement method: Pulse wave oscillation
2.Work pattern: Manual / automatic
3.The measurement interval of the automatic measurement mode:1,2,3,4,5,10,15,30,60,90,120,180,240,480 min
4.Measurement time of the continuous: 5 Minutes
5.Measuring range
5.1Adult
① SYS: 40~270mmHg
② DIA: 10~210mmHg
③ MEAN: 20~230mmHg
5.2Children
① SYS: 40~200mmHg
② DIA: 10~150mmHg
③ MEAN: 20~165mmHg
5.3Neonatus
① SYS: 40~135mmHg
② DIA: 10~95mmHg
③ MEAN: 20~110mmHg
6.Static pressure Measuring range: 0~300mmHg (0-40kPa)
7.Static pressure precision: ±3mmHg

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
ETERFANT 8" Patient Monitor ICU CCU Vital Sign For Hospital NIBP, SPO2, PR,TEMP(PM80B)

Standard Parameters:
NIBP, SPO2, PR,TEMP

Features:
1.Compact and flexible appearance.
2.Simple and convenient operation, which is applicable for community medical treatment and family ect.
3.8 inch high resolution color TFT display.
4.Adjustable audible and visual alarms.
5.Built-in rechargeable lithium battery for uninterrupted monitoring.

Technique Specification:
1.SPO2
①Measuring Range: 0 ~ 100 %
②Resolution: 1%
③Accuracy: 70% ~ 100% (2 %)
④Pulse Rate: 20-250 BPM
⑤Resolution: 1 BPM
⑥Accuracy: 3 BPM

2.NIBP
2.1.Method: Oscillometry
2.2.Measure mode: Manual, Auto, STAT
2.3.Unit: mmHg, kPa
2.4.Measure and alarm range:
2.5.Adult Mode
①SYS 40 ~ 280 mmHg
②DIA 10 ~ 225 mmHg
③MEAN 20 ~ 240 mmHg
2.6.Pediatric Mode
①SYS 40 ~ 220 mmHg
②DIA 10 ~ 160 mmHg
③MEAN 20 ~ 170 mmHg
2.7.Neonatal Mode
①SYS 40 ~ 135 mmHg
②DIA 10 ~ 100 mmHg
③MEAN 20 ~ 110 mmHg
2.8.Resolution: 1mmHg
2.9.Accuracy: 5mmHg

3.TEMP
①Measure and Alarm Range: 0 ~ 50 C
②Resolution: 0.1C
③Accuracy: 0.1C

Standard Configuration:
1.Main Unit *1
2.Adult Spo2 probe *1
3.Adult NIBP cuff *1
4.NIBP extension tube *1
5.Power Cable *1
6.Power adapter *1
7.User Manual *1
8.Temperature probe *1  
/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
 
15.6" Patient Monitor ICU CCU Vital Sign For Hospital ECG NIBP RESP TEMP SPO2 PR(PM15B)

Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR

Features:
1.15.6 inch large screen for viewing convenience.
2.Three Working Modes: Monitoring, Surgery and Diagnosis.
3.Simple and friendly operating display interface.
4.Multi-display modes suitable for different applications: Standard Interface, Large font, ECG Standard Full Display, OXY , Trend Table, BP Trend.
5.Built-in high capacity battery up to 3 hours of continuous work.
6.VGA output for external display.

Technique Specification:
ECG
1.Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V)
2.Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
3.Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
①Resolution: 1 BPM
②Accuracy: ±1%
③Sensitivity >200 uV(Peak to peak)
4.ST measurement range: -2.0 ~ +2.0 mV
①Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
②Other Range: unspecified
5.Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
6.Bandwidth:
①Diagnostic: 0.05~130 Hz
②Monitor: 0.5~40 Hz
③Surgery: 1~20 Hz

SPO2
1.Measuring Range: 0 ~ 100 %
2.Resolution: 1%
3.Accuracy: 70% ~ 100% (2 %)
4.Pulse Rate: 20-250 BPM
5.Resolution: 1 BPM
6.Accuracy: 3 BPM

NIBP
1.Method: Oscillometry
2.Measure mode: Manual, Auto, STAT
3.Unit: mmHg, kPa
4.Measure and alarm range:
4.1Adult Mode
①SYS 40 ~ 280 mmHg
②DIA 10 ~ 225 mmHg
③MEAN 20 ~ 240 mmHg
4.2Pediatric Mode
①SYS 40 ~ 220 mmHg
②DIA 10 ~ 160 mmHg
③MEAN 20 ~ 170 mmHg
4.3Neonatal Mode
①SYS 40 ~ 135 mmHg
②DIA 10 ~ 100 mmHg
③MEAN 20 ~ 110 mmHg
5.Resolution: 1mmHg
6.Accuracy: 5mmHg

RESP
1.Method: Impedance between RA-LL or RALA
2.Measurement Range:
①Adult: 10 ~ 120 BrPM
②Neonatal / Pediatric: 7 ~ 150 BrPM
3.Resolution: 1 BrPM
4.Accuracy: 2 BrPM

TEMP
1.Measure and Alarm Range: 0 ~ 50 C
2.Resolution: 0.1C
3.Accuracy: 0.1C

Standard Configuration:
1.Main Unit *1
2.5-lead ECG cable *1
3.Disposable ECG Electrode *5
4.Adult Spo2 probe *1
5.Adult NIBP cuff *1
6.NIBP extension tube *1
7.Temperature probe *1
8.Power Cable *1
9.User Manual *1
10.Fuse *1  
 
 
FDA Statement:
The sale of this item may be subject to regulation by the U.S. Food
and Drug Administration and state and local regulatory agencies.
So you can bid it on this item only if you are an authorized purchaser.
If the item is subject to FDA regulation,We have to verify your status
as an authorized purchaser of this item before shipping of the item.
Thanks for your understanding!
PushAuction