Introduction
ECG1200G is an  electrocardiograph which can collect 12-lead ECG signal simultaneously and print  ECG waveform with thermal printing system. It features in, recording and  displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG  waveform parameters automatically, prompting for “Lead off” and “Lack of paper”,  multi-language interface, AC/DC, selecting rhythm lead, printing the trend chart  and histogram of P-R interval, case database management.

Function
1)Sync collection for 12-lead  ECG, adopt digital signal processing technology and get high-quality ECG  waveform via power frequency filter, baseline filter and EMG filter of ECG  signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed  and filter state, etc. on one screen, convenient for contrastively  diagnosing.
3)Multiply printing modes and formats, including auto 12x1, auto  6x2+1, auto 6x2+1_H, auto 6x2, auto 6x2_H, auto 3x4+1, auto 3x4+2, rhythm 12,  rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R  interval can be printed, waveform length printed can be adjusted, and with time  print function, which meets different requirements.

4)Paper speed: 5mm/s,  6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
5)With the functions of  auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement  results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS  Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5),  S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
6)Built-in memory  stores up to 1000 cases, convenient for case review and  statistic.
7)Multi-language(Turkish, French, Chinese, English, German,  Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian)  interface and report.
8)In optimal DC state, up to 10-hour standby time,  continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is  3s case), which meets the requirements of visiting a patient at home and body  examination.

Performance
Input mode: floating and  defibrillation protection
Frequency response: 0.05Hz ~  150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)

Time constant:≥  3.2s
Patient leak current: <10µA
Calibration voltage:  1mV
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity:  10mm/mV±2%
Noise level: ≤15µVp-p
Input circuit current: ≤50nA
Input  impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I,  type CF and defibrillation-proof applied part
Recording mode: thermal  printing system
Paper size: 210mm(W)×20m(L)
Sampling frequency:  1000Hz
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter:  AC 50Hz/60Hz(-20dB)
Paper speed:
Auto: 25, 50mm/s, ±5%
Rhythm: 25,  50mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
Auto record: set  record according to auto record format and mode, automatically switching leads,  measuring and analyzing.
Rhythm record: set record according to rhythm record 

format and mode, automatically measuring and analyzing.
Manual record: set  record according to record format, manually switching leads.
Measurement  parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T  interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Power  supply:
AC: 100V~240V(50/60Hz)
DC: 14.8V/3500mAh rechargeable lithium  battery
Fuse specification: two AC time lag fuse(φ5×20mm),  T1.6AL250V
Waterproof degree: IPX0
Working mode: continuous  working

Accessories
Standard:
A lead cable
A  limb electrode
A chest electrode
A thermal recording paper
A power  cord
An earth wire

A user manual



Physical characteristic
Working  environment
Temperature: 5℃~40℃
Relative humidity:  25%~95%(non-condensing)
Atmospheric pressure: 700hPa~1060hPa
Transport and  storage environment
Temperature: -40℃~+55℃
Relative humidity:  ≤95%
Atmospheric pressure: 500hPa~1060hPa
Dimension: 340mm(L) × 320mm(W) ×  85mm(H)
Weigh: 3.2Kg