2/4 Holes Portable Dental Turbine Unit Work for Air Compressor w/3 Way Syringe

TU01(4Holes)

 
Important reminder:

To avoid the problem of speed loose control and maintain long lifespan of this machine,please do turn the speed to "min" with the speed controller before start the following operation : push "on"or"off" button,Switching bur running between clockwise and reversed or Switching control between manual and foot pedal.

Portable Dental Turbine Unit handpiece Compressor 4H
Note: it does not include the compressor
 

comprise:

1 X Dental Turbine Unit

1 X 3 way syringe

1 X water bottle

1 X foot switch

1 X plastic tube for connection to air compressor

Technical Parameter:

Water pressure: 0.1Mpa~0.25Mpa

Air pressure for handpiece: 0.01Mpa~0.4Mpa

Weight: 1.6kg

Size: 160mmX120mmX80mm( L X W X H)

Just connect to air compressor (0.4Mpa~0.8Mpa required) to get start

 
 
Note:If you received the item and found the unit and foot controller has scratches ,don't worry,it is the protective film been scratched,just remove it and then you will get a totally new item.


 

TU04(2Holes)
 
 
package listing:
1 X Dental Turbine Unit
1 X 3 way syringe
1 X water bottle
1 X foot switch
1 X plastic tube for connection to air compressor
note:not inculde compressor
 
Specifications

1.easy to operation.
2.best price with good quality

Dental portable turbine controller
1. Water pressure: 0.1Mpa~0.25Mpa
2. pressure for handpiece: 0.01Mpa~0.4Mpa.
3. Air pressure input: 4~8kg
4. Air pressure output: 0~4kg
5. Air pressure to handpiece: 0.01Mpa~0.4Mpa+C317a
6. Water pressure output: 0~2kg
7. Size: 160mmx120mmx80mm

PAY ATTENTION: PLEASE DON'T DROP THE TURBINE UNIT'S TUBE ON THE GROUND, WHICH WILL LEAD TO YOU CAN'T CONNECT THIS TO HANDPIECE.


Feature:

1. connect the air surce with the fast interface conect water source with filters.
2. according to different requirement,connect it with diff extrernal accessories and equipment.
3.turn on water vapor switch.
4.seart up food control regulate the water and air to kthe standard of commonly using.
5.turn off the water after work.shut off the air source.
6. connect it with high-speed handpiece, adjustable pneumatic to 0.2mpa, and adjust the conditioning cooling water to be like frost when the handpiece works.
 
 
Note:If you received the item and found the unit and foot controller has scratches ,don't worry,it is the protective film been scratched,just remove it and then you will get a totally new item.
 
 
Statement (FDA, ARTG)
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and
state and local regulatory agencies. If the item is subject to FDA regulation,
I will verify your status as an authorized purchaser of this item before shipping of the item.
If you have questions about legal obligations regarding sales of medical devices,
you should consult with the FDA's Center for Devices and Radiological Health:
https://www.fda.gov/cdrh/devadvice/
https://www.fda.gov/cdrh/industry/support/index.html
Thank you for your cooperation.
We try our best to reply to your emails as soon as possible, however, due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately.
Please give us the opportunity to resolve any problem. We understand the concerns and frustrations you might have, and will try our best to resolve the issues.
we hope you have a exciting ebay shopping experience and enjoy it!
we are expecting Good co-operation with you and hope to see you again!
If you have any other questions, please feel free to contact us. 100% customer satisfaction guarantee is our goal.
PushAuction
Datacaciques