ETERFANT 18L Dental Autoclave Steam Sterilizer Medical Sterilization
Key Features:
- Cycle progresses automatically through conditioning, sterilizing, exhaust, and venting phases.
- Constructed from SUS304 or SUS316L stainless steel for durability and corrosion resistance.
- Two sterilization temperatures: 121°C/134°C, auto-starts once reached.
- Timer starts only after preset temperature is achieved, ensuring full sterilization.
- Manual door operation via rotating handle.
- Silicone rubber seals ensure uniform pressure sealing.
- High-capacity cylindrical chamber for diverse sterilization needs.
Parameters:
Rated Working Pressure: 0.22 MPa
Rated Voltage: AC220 V + 22 V, 50 + 1 Hz
Input Power: ≤ 1800 VA
Sterilization Temperature: 121℃ /134℃
Water Tank Volume: About 1 Liter
Noise: <70 db
Notes:
- Please do not place the sterilizer on an unstable worktable, such as a shaking table, slope, or the position of the vibration.
- Do not share the same electric outllet with other electrical apparetus.
- Please pay attention to correct voltage and frequency.
- Please do not block or cover the sterilizer door and vent.
- Please do not place anything on the sterilizer.
- Please close steam discharge valve before the disinfection.
- Before each use, must supply 800ml of distilled water .
- You can close the door after the tray is placed well. Turn the door handle clockwise until the door control light is green.
- The door handle of the sterilizer should be screwed tightly, otherwise the sealing ring will burst out during the sterilization process.
- When the pressure drops to 0 and wait 1-2 minutes, you can open the door.
- Always use the anti-heat gloves to load or unload the tray into the sterilizer in order to avoid scald.
Package Contents:
- 2 x Instrument Tray
- 1 x Instrument Tray Rack
- 1 x Protective Glove
- 1 x Draining Hose
- 1 x Instructions
- 1 x Door Seal
/////////////////////////////////////////////
18L Class B Dental Autoclave Vacuum Medical Drying Steam Sterilizer LCD+Printer
Description:
This tabletop sterilizer is designed for efficient and thorough sterilization processes. It consists of a sterilization chamber, instrument trays, water tank, control system, and power system. The inner chamber is crafted from high-quality SUS304 or SUS316L stainless steel, ensuring durability and resistance to corrosion.
Technical Parameters:
1. Rated Working Pressure: 0.22 MPa
2. Rated Voltage: AC 110V, 60Hz
3. Input Power: ≤ 2200 W
4. Sterilization Temperature: 121°C
5. Noise Level: < 70 dB
6. Weight: 43kg
7. Product Size: 64 x 48 x 45cm
Packing List:
- Instrument Tray x 3
- Instrument Tray Rack x 1
- Heat-Resistant Glove x 1
- Door Adjustment Wrench x 1
- Drain Pipe x 1
- User Manual x 1
- Door Seal Ring x 1
- Drain Plug & O-Ring x 2
Features:
1. 12 preset sterilization programs to suit various sterilization needs.
2. Built-in thermal printer for convenient record-keeping.
3. Safety valve automatically releases pressure when internal pressure is too high.
4. Power fuse automatically disconnects the circuit in case of excessive current or temperature due to short circuits or other issues.
5. Equipped with an LCD screen featuring soft light for comfortable viewing.
6. One-click component fault self-test function for easy maintenance.
7. 99% saturated steam ensures thorough sterilization.
Intended Use:
Ideal for dental clinics, laboratories, and other medical facilities where efficient and reliable sterilization of instruments is crucial.
Precautions:
- Ensure the device is placed on a stable and level surface.
- Regularly clean and maintain the sterilizer to ensure optimal performance.
- Always follow the operating instructions carefully to avoid damage or accidents.
///////////////////////////////////////////////////////////////
USA Dental Medical Autoclave Steam Sterilizer 16L Drying Function JCH-16
Features:
1.Lock system: Double control with Air pressure and mechanical lock.
2.Automatic temperature control to prevent dry burning.
3.Safety: Over-heat protection/Safety valve.
4.304 stainless steel chamber.
5.Motorola Pressure Sensor.
6.With drying function.
Installation:
1. First time to use this sterilizer, should need to adjust those two front feet. To make them higher than the end two. It will make chamber add with more distilled water.
2. The machine should be placed on the flat position horizontally. Then take out the bottom plate and add water into the chamber slowly. Be sure those heating elements should be covered by water completely. Keep machine 10cm distance away from the walls.Connect the drain tube with steam vent in the back of sterilizer. Make sure the drain tube was inserted fully and secured with clamp. Another side of drain tube should be fixed and collected with sewer or barrel.
3. Recommended injection water volume (raising feet to highest ): 950-1000ml.
4. Place the heat-insulating plate above heating bar. And put silicone strip at chamber mouth.
5. The outlet end of the drain pipe cannot contact with the surface of sewage. To prevent sewage suction back to chamber during cooling down.
6) Tips for placing sterilization pouches: Place pouches with paper side facing down in a staggered manner. To avoid causing wet packaging.
Sterilization process introduce:
1. "134℃ Program" button:
Heating to pressure 0.70bar(HE.1)-the first exhaust (ГE.1)-Heating to pressure 1.70bar (HE.2)-the second exhaust (ГE2)-Heating to pressure 2.20bar (HE.3)- Start 135°C Sterilization (Lasts 6minutes)-the third exhaust (ГE.3)Balance to pressure 0.00bar (LED display “END”)- open the door (Sterilization completed).
2. "121℃ Program" button:
Heating to pressure 0.70 bar (HE.1)-the first exhaust (ГE.1)-Heating to pressure 1.00bar (HE.2)the second exhaust (ГE.2)-Heating to pressure 1.20bar (HE.3)- Start 122℃ Sterilization(Lasts 25minutes)-the third exhaust (ГE.3)-Balance to pressure 0.00bar (LED display “END”)-open the door (Sterilization completed).
3. "Dry Program" button:
Caution: Confirm that door was not closed, DRY would not able to be started after door was closed.
Click the“DRVAbutton to make indicator lighting. Click the “START” button during indicator is lighting (5 seconds). Pressure window will showing 19 seconds counting. Means drying was started. If the drying effect is not as expected, can run the drying again.
Specification:
1. Chamber size: Ф23cmX36cm
2. Machine size: 47.5*38.5*36.5cm
3.Machine weight: GW:28.8kg/N.W:27.3kg
4. Power: AC110V 60Hz/1500VA;
5. Sterilization temperature/sterilization pressure: 121℃-1.2bar/134℃-2.2bar
6. Sterilization time: 25Min(121℃)/6Min(134℃)
Accessories:
1.Tray and rack* 1Set
2.Tray holder* lpc
3.Ф 13 clamp*1pc
4.Ф 12 Drain tube-2m* 1pc
5.Fuse *2pcs
6.500ml Measuring cup* 1 pc
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
USA Dental Medical Autoclave Steam Sterilizer 18L Drying Function JCH-18
Features:
1. Lock system: Double control with Air pressure and mechanical lock.
2. Automatic temperature control to prevent dry burning.
3. Safety: Over-heat protection/Safety valve.
4. 304 stainless steel chamber.
5. Motorola Pressure Sensor.
6. With drying function.
Installation:
1. To use this sterilizer for the first time, adjust the two front feet so they are higher than the back two. This will enable the chamber to hold more distilled water.
2. To set up the machine, first, place it horizontally on a flat surface. Next, remove the bottom plate and slowly add water into the chamber, ensuring that the heating elements are completely submerged. Maintain a distance of at least 10 cm between the machine and any walls. Then, connect the drain tube to the steam vent located at the back of the sterilizer. Make sure the drain tube is fully inserted and secured with a clamp. The other end of the drain tube should be properly fixed and directed to a sewer or a collection barrel.
3. Recommended injection water volume (raising feet to highest ): 950-1000ml.
4. Place the heat-insulating plate above the heating bar. And put a silicone strip at the chamber mouth.
5. The outlet end of the drain pipe must not contact the sewage surface to prevent backflow into the chamber during cooling.
6. Tips for placing sterilization pouches: Place pouches with paper side facing down in a staggered manner. To avoid causing wet packaging.
The sterilization process introduces:
1. "134℃ Program" button:
Heating to pressure 0.70bar(HE.1)-the first exhaust (ГE.1)-Heating to pressure 1.70bar (HE.2)-the second exhaust (ГE2)-Heating to pressure 2.20bar (HE.3)- Start 135°C Sterilization (Lasts 6minutes)-the third exhaust (ГE.3)Balance to pressure 0.00bar (LED display “END”)- open the door (Sterilization completed).
2. "121℃ Program" button:
Heating to pressure 0.70 bar (HE.1)-the first exhaust (ГE.1)-Heating to pressure 1.00bar (HE.2)the second exhaust (ГE.2)-Heating to pressure 1.20bar (HE.3)- Start 122℃ Sterilization(Lasts 25minutes)-the third exhaust (ГE.3)-Balance to pressure 0.00bar (LED display “END”)-open the door (Sterilization completed).
3. "Dry Program" button:
Caution: Ensure the door is open; DRY cannot start if closed.
Click the “DRVA” button to make indicator lighting. Click the “START” button while the indicator is lighting (5 seconds). The pressure window will show a countdown of 19 seconds, indicating that the drying process has started. If the drying results are not satisfactory, you can repeat the drying process.
Specifications:
1. Chamber size: Ф25cmX35.5cm
2. Machine size: 47.5*38.5*36.5cm
3. Machine weight: G.W:29.9kg, N.W:28.4kg
4. Power: AC110V 60Hz/1500VA;
5. Sterilization temperature/sterilization pressure: 121℃-1.2bar/134℃-2.2bar
6. Sterilization time: 25Min(121℃)/6Min(134℃)
Accessories:
1. Tray and rack* 1 set
2. Tray holder* 1pc
3. Ф 13 Clamp* 1pc
4. Ф 12 Drain tube-2m* 1pc
5. Fuse* 2 pcs
6. 500ml Measuring cup* 1 pc
//////////////////////////////////////////////////////////////////////////////////////
ETERFANT USA Dental Medical Autoclave Steam Sterilizer 23L Drying Function JCH-23
Key Features:
- Dual Safety Locking System: Combines pneumatic pressure control with a mechanical lock.
- Automatic Temperature Control: Prevents dry-firing for safety and component longevity.
- Comprehensive Safety: Equipped with overheat protection and a pressure relief safety valve.
- Premium Construction: Features a durable 304 stainless steel inner chamber.
- Precision Monitoring: Utilizes a Motorola pressure sensor for accurate readings.
- Integrated Drying Cycle: Includes an efficient drying function post-sterilization.
Installation Tips:
1. On first use, adjust the two front feet higher than the rear feet. This allows maximum distilled water capacity.
2. The machine should be placed on the flat position horizontally. Then take out the bottom plate and add water into the chamber slowly, ensuring the heating element is fully submerged. Maintain a 10 cm clearance from walls. Connect the drain tube with steam vent in the back of sterilizer. Make sure the drain tube was inserted fully and secured with clamp. Route the free end to a drain or container.
3. Recommended water volume (Max Height): 950-1000ml.
4. Place the heat-insulating plate above heating bar. And position silicone strip around the chamber opening.
5. Never allow the drain outlet to contact standing water, preventing backflow into the chamber during cooling.
6. Tips for placing sterilization pouches: Place pouches paper-side down in a staggered arrangement to prevent wet packs.
Sterilization Process Introduction:
1. "134℃ Program" Button:
Heating to pressure 0.70 bar(HE.1)-First exhaust (ГE.1)-Heating to pressure 1.70 bar (HE.2)-Second exhaust (ГE2)-Heating to pressure 2.20 bar (HE.3)- Start 135°C Sterilization (for 6 minutes)-Third exhaust (ГE.3)-Balance to pressure 0.00 bar (LED display “END”)- Open the door (Sterilization completed).
2. "121℃ Program" Button:
Heating to pressure 0.70 bar (HE.1)-First exhaust (ГE.1)-Heating to pressure 1.00 bar (HE.2)-Second exhaust (ГE.2)-Heating to pressure 1.20 bar (HE.3)- Start 122℃ Sterilization(for 25minutes)-Third exhaust (ГE.3)-Balance to pressure 0.00 bar (LED display “END”)-Open the door (Sterilization completed).
3. "Dry Program" Button:
Caution: Ensure the door is not closed. The drying program will not start if the door is closed.
Press the“DRVA button to light up the indicator. Press the “START” button while indicator is lit within 5 seconds. The display will show a 19-second countdown, confirming the drying cycle is active. If the drying effect is not as expected, rerun the drying cycle.
Specification:
Chamber Size: Ф25 cmX45 cm
Machine Size: 57.5 x 38.5 x 36.5cm
Machine Weight: G.W: 33.8 kg, N.W:32.3 kg
Power: AC 110 V 60 Hz/1500 VA
Sterilization Temperature/Sterilization Pressure: 121℃-1.2bar/134℃-2.2bar
Sterilization Time: 25 Min(121℃)/6 Min(134℃)
Package Contents:
- 1 x Tray and Rack
- 1 x Tray Holder
- 1 x Ф 13 Clamp
- 1 x Ф 12 Drain Tube
- 2 x Fuse
- 1 x 500ml Measuring Cup
//////////////////////////////////////////////////////////////////////////
12L Class B Dental Autoclave Pulse Vacuum Steam Sterilizer Sterilization DGT-12B Dry Function
The tabletop sterilizer consists of a sterilization chamber, instrument trays, water tank, control system, and power system. The inner chamber is made of SUS304 or SUS316L stainless steel, formed by pressing.
Technical Parameters:
1.Rated Working Pressure: 0.22 MPa
2.Rated Voltage: AC 110V, 60Hz
3.Input Power: ≤ 2200 W
4.Sterilization Temperature: 121°C / 134°C
5.Noise Level: < 70 dB
6.12L Weight: 40kg
7.12L Product Size: 58 x 44.5 x 40cm
Packing List:
Instrument Tray x 3
Instrument Tray Rack x 1
Heat-Resistant Glove Set x 1
Door Adjustment Wrench x 1
Exhaust Water Pipe x 1
Water Inlet Pipe x 1
Instruction Manual x 1
Door Seal x 1
Filter x 1
//////////////////////////////////////////////////////////////////////////
//////////////////////////////////////////////////////////////////////////