Series AMS 300i
Application Collision protection of cranes / gantry cranes
Positioning of electroplating plants
Positioning of skillet systems and side-tracking skates
Positioning of stacker cranes
Order guide Reflective tape must be ordered separately
Light source Laser, Red
Laser class 2, IEC/EN 60825-1:2014
Light spot size [at sensor distance] 100 mm [120,000 mm]
Measurement value calculation time 8 ms
Measurement range 200 ... 120,000 mm
Resolution 0.001 ... 10 mm
Accuracy 2 mm
Reproducibility (3 sigma) 1.5 mm
Measurement value output 1.7 ms
Max. traverse rate 10 m/s
Supply voltage UB 18 ... 30 V, DC
Type PROFIBUS DP, SSI
Transmission speed 0.0096 ... 12 Mbit/s
Clock frequency 50 ... 800 kHz
Type of connection Connector
Designation on device BUS IN
Thread size M12
Material Metal
No. of pins 5 -pin
Function BUS OUT
Data interface
PROFIBUS OUT
Type of connection Connector
Designation on device BUS OUT
Thread size M12
Type Female
No. of pins 5 -pin
Encoding B-coded
Function PWR / SW IN / OUT
Voltage supply
Type of connection Connector
Designation on device PWR
Thread size M12
Type Male
No. of pins 5 -pin
Encoding A-coded
Function Service interface
Type of connection Connector
Designation on device SERVICE
Thread size M12
Type Female
No. of pins 5 -pin
Encoding A-coded
Function Data interface
SSI
Type of connection Connector
Designation on device SSI
Thread size M12
Type Male
No. of pins 5 -pin
Encoding B-coded
PushAuction