Product Overview:
Measure three-phase AC voltage, current, active power, reactive power, apparent power, total power, the phase between current and voltage, the phase between phase voltage, frequency, electric energy, phase sequence, etc
Main Features:
1. Adopt rogowski coil/ flexible coil, small volume and light weight, especially convenient for field measurement. | ||||
2. Coil size:φ200mm, can be customized size according to user requirements. | ||||
3. Multiple parameters are displayed on the same screen, easy to operate. | ||||
4. With USB interface, upload the storage data to the computer through the system software, convenient to reading, saving, printing and so on. |
Technical parameters:
Clamp Size | Φ 200mm | |||
Weight | 266g (include battery) | |||
Meter Size | 200mmX370mmX35mm | |||
Current Measurement | Range: AC 0.0A~6000A | Accuracy: ±0.5%Fs | Resolution 0.1A | |
Voltage Measurement | Range: AC 0.01V~600V | Accuracy: ±0.5%Fs | Resolution: 0.01V | |
Active Power Measurement | Range: 0.00W~3600kW | Accuracy: ±1%Fs | Resolution: 0.01W | |
Apparent Power Measurement | Range: 0.00VA~3600kVA | Accuracy: ±1%Fs | Resolution: 0.01VA | |
Reactive Power Measurement | Range: 0.00var~3600kvar | Accuracy: ±1%Fs | Resolution: 0.01var | |
Power Factor Measurement | Range: 0.300~1.000 | Accuracy: ±1%Fs | Resolution: 0.001 | |
Electric Energy Measurement | Range: 0.00Wh~360000kWh | Accuracy: ±1%Fs | Resolution: 0.01Wh | |
Frequency Measurement | Range: 25.0Hz~600.0Hz | Accuracy: ±0.5Hz | Resolution: 0.1Hz | |
Phase Measurement | Range: 0.0°~360.0° | Accuracy: ±0.5° | Resolution: 0.1° | |
Power Supply | 6V DC(LR03X4PCS) | |||
Working Current | Backlight open 80mA; Backlight close 50mA | |||
Sampling Rate | 2 times/second | |||
Frequency | 50Hz/60Hz automatic identification | |||
Communication Interface | With USB interface, storage data can be uploaded to computer, convenient to data analyze, communication cable length: 1.8m | |||
Data Storage | 200 groups , flash display “FULL” symbol indicate storage full | |||
Data Hold | Data hold function: “HOLD” symbol display | |||
Overflow Display | Over range overflow function: “OL” symbol display | |||
Auto Shut Down | 15 minutes after power on, it will shut down automatically without any operation to reduce the power consumption. | |||
Battery Voltage | While battery voltage is lower than 4.8V. low battery voltage symbol “ ” display, remind to replace the battery | |||
Backlight | Yes, Controlled by “ * ”key | |||
Working Temperature | -10℃~40℃; Below 80%RH | |||
Accessories | Meter: 1PCS; Test Wires: 4PCS (each of yellow, green, red, black); USB communication cable: 1PCS; LR03 Battery: 4PCS ; Meter bag: 1PCS | |||