Crane Anemometer Tower Crane Anemometer Wind Speed Sensor Breeding 24V Crane Anemometer
The tower head is inserted into 220V socket, the alarm light flashes, this is the self-test process, to be 4 windows digital stability, that is, the working state.
Press the setup button once, set the fan +0.5 level, 3-10 level cycle setting, when the wind speed is greater than the setup level, the device is in the alarm state, the buzzer sound alarm, the alarm window has a red light flashing.
At the same time, the internal relay status is flipped. Normally open to short circuit, normally closed to open circuit.
(This function is an extension of the function, customers can add other functions. (This function is an extended function, which can be added by customers, such as: sound and light alarm for power failure, etc.)
Product installation
Installation of the main unit: The main unit is installed in the driver's cab, and a stable and solid position should be chosen. Give full consideration to the length of the power line and the vibration of the tower to ensure that the mainframe can not be loosened in the process of use.
Sensor Installation:The sensor of the anemometer is installed on the top of the driver's cab, when installing, it should be ensured that the installation position is horizontal, and it can't fall off during the work of the tower crane.
No
Remarks: 0* shielded cable is attached to connect with the mainframe.