US BEING Dental High Speed Handpiece For KaVo MULTIflex Coupler 4 Hole Bearings
Shipping directly from Walnut, California 91789 United States

2PQ2-K Handpiece
  • Original BEING, top quality
  • High Speed Handpiece
  • Big Torque Head
  • For KAVO MULTIflex / MULTIflex LUX Coupling 
  • Ceramic ball bearings; Computer balanced rotor
  • Ensure an extremely long service life and smoother vibration-free performance
Features:
  • New triple water spray system can cool the treated area and the bur effectively and roundly. Clogging of the the spray port is thus minimized.
  • Ceramic ball bearings, Computer balanced rotor, with high cutting efficiency and less vibration and noise.
  • The NON-RETRACTION structure in the handpiece, prevents suction of oral fluids in a patient's mouth into the water line of the handpiece at the spray water outlet port.
  • Newly-designed handle, comfortable to hold and easy to clean.
  • Handpiece is autoclavable. (up to 135℃)
Technical Specifications:
  • Rotation Speed: 380000--450000 rmp (Standard Head)
  • Head Dimension: 13.14mm x 10.8mm (Standard Head)                 
  • Bur Applicable: φ1.59mm~φ1.6mm × 21mm~23mm (diameter × length)
  • Noise: ≤70dB
4 Holes KAVO MULTIflex Coupling
  • BEING Brand 
  • For KAVO MULTIflex / MULTIflex LUX
  • 4 Holes connection
  • Without LED light
  • 360 degree swivel
  • Anti retraction
  • Autoclavable
  • Easy to load or unload the handpiece from the tubing of the dental unit
Replacement Rotor
  • BEING original, top quality
  • Big Torque Head
  • For BEING 2PBQ2-K (302PBQ-K) / 2PBQ2-N (302PBQ-N) / 2PBQ-S (302PBQ-S) / 2PQ2-K (302PQ-K) / 2PQ2-N (302PQ-N) / 302PB high speed handpiece
  • Push button
  • With closed ceramic bearings
  • All turbines are dynamically balanced
  • Low noise, durable

FAQ

Q: What coupler is required for this 2PQ2-K handpiece?
A: It works with KaVo MULTIflex / MULTIflex LUX 4-hole coupling without LED.

Q: What is anti-retraction structure?
A: It prevents oral fluids from being sucked back into the handpiece water line after stopping water spray to reduce cross-contamination risk.

Q: What bur can be used on this handpiece?
A: Standard FG burs with diameter φ1.59~1.6mm and length 21–23mm.

Q: What is the max sterilization temperature?
A: Handpiece and coupler can be autoclaved up to 135°C.

Q: Can this replacement rotor fit standard head 3PQ2-K handpiece?
A: No, this rotor is only for big torque head 2PQ2-K / 2PBQ2-K series handpiece, not for standard mini head.