The clamp-shaped ground resistance tester is controlled by a microprocessor to accurately detect the ground resistance. It uses a filtering technology to minimize the interference. It is a commonly used and necessary instrument for telecommunication, electric , meteorology, engine room, oil field, electromechanical installation and maintenance as well as industrial enterprise departments using electric .
Features:
Easy to Operate: When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, safer and faster.
Clamp Head Design: Using core and winding, stable, precise and strong -interference. Clamp Size: Φ1.26"(32mm), large jaws with double insulation for extra safety.
Data Storage Function: 500 sets of measurement results can be recorded, the "MEM" storage indication, flashing the "MEM" indicating that the storage is full.
Multi Practical Functions: New design, panel operation with 6 buttons, better performance. With real- , data storage, data access, , automatic shutdown and other functions.
Widely Used: It is suitable for measuring all kinds of telecommunications, electric , meteorology, machine room, oil field, distribution lines, tower transmission lines, stations, factory grounding network, rob and other grounding resistance.
Specifications:
Model: ST4100 / ST4800
(Optional)
Material: ABS
Function: Grounding resistance test, circuit resistance test, leakage current test
Environmental and Humidity: 23℃ ± 5℃, lower than 75%RH
: , 4 * 1.5V AA dry
(not included)
Measurement Method: Mutual feeling way
Resistance : 0.010Ω-500Ω (ST4100), 0.010Ω-1200Ω (ST4800)
Resistance Resolution: 0.001Ω
Current : 0.00mA-30.0A (ST4800)
Current Resolution: 0.01mA
Clip Size: 55mm x 32mm
Feature: Have
+ ASynchronous Display: + AThe same screen display
Display Mode: 4-bit LCD display, black screen design
LCD Size: 46mm x 36mm
Measure : 1 /second
Data Storage: 500 groups, the "MEM" storage indication, flashing the "MEM" indicating that the storage is full
Data Access: The "MR" indicates when reviewing the data
Overflow Display: OL indication when overrange overflow
Disturbed Test: Automatic identify the interference signal, indicating the "NOISE" when the interference current is high
Function: Send an prompt when the measured value exceeds the set point
Cell Voltage: is displayed in real
Auto Shut Off: It can be set to 5, 10, 15, 20 minutes, OFF, OFF means to cancel the automatic shutdown, the default is 5 minutes
Dissipation: 115mA
Working and Humidity: -10℃~40℃; lower than 80%RH
Storage and Humidity: -20℃~60℃; lower than 70%RH
Insulation Resistance: 20MΩ above (Between the circuit and the housing 500V)
Withstand Voltage: AC 3700V/rms (Between the circuit and the housing)
External Field: <40A/m
External Electric Field: <1V/m
Suitable For Safety Regulation: IEC61010-1( III 300V, 150V, degree of pollution 2); IEC61010-031; IEC61557-1 (earthing resistance)
Item Size: 295 * 85 * 58mm / 11.61 * 3.35 * 2.28in
Item Weight: 888g / 1.96lb
Package Weight: 1970g / 4.34lb
Package Size: 35 * 13 * 21cm / 13.78 * 5.12 * 8.27in
Package List: E25030-1
1 * Earth Resistance Tester
1 *
1 * Measuring
1 * User Manual (English)