Digital Clamp On Earth Resistance Tester Loop Ground Resistance Meter 0.01-200Ω

 !!!!Battery not included during The Shipping!!!

Introduction:

Clamp Earth Resistance Tester is widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment, etc. 

When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster. 

ETCR Clamp Earth Resistance Tester can measure the ground fault which can not be measured by traditional method, can apply in the occasion where traditional methods are unworkable

ETCR Clamp Earth Resistance Tester measures the integrated value of ground resistance and resistance lead.


Specifications:

Function: Ground resistance test, Loop  resistance test

Power Supply: 6VDC (4 PCS of AA Alkaline batteries are not included)

Resistance Range: 0.01-200Ω

Resistance Resolution: 0.001Ω

Highest Resistance Accuracy: ±1%±0.01Ω

Data memory: 99 Sets

Alarm Threshold Setting Range: Resistance: 1-199Ω

Alarm Sound and Light:Beep-beep-beep alarm tone, Alarm  Symbol Flashing, Press AL key to turn on, turn off Alarm or set  Alarm Threshold.

Interference Signal Recognition:Beep-beep-beep tone, NOISE symbol  blinking

Working Temperature and Humidity: -20-55℃;20RH-90RH

LCD Screen: 4 Digits LCD display, Screen L×W:  47mm×28.5mm

Clamp Size: 65mm × Φ32mm

Clamp Opening Extent: 32mm

Tester Weight: 1160g (With batteries)

Clamp Dimension: L×W×T: 285mm×85mm×56mm

Protection Level: Dual Insulation

Structural Feature: Clamp CT

Shifting: Automatic shifting

External magnetic field: 40A/m

External electrical field: 1V/m

Single measurement time: 0.5 second

Resistance measurement frequency: 1KHz

Measured current frequency: 50/60Hz Automatic measurement

Low Battery Indication: Low battery symbol displays when  battery is lower then 5.3V

Memory Full Indication: MEM symbol blinks when all 99 sets  memory is full

Over Range Indication: Out of range indication OLΩ”L0.01  or OL A

Auto Power-off: 5 minutes after Boot up

Power Consumption:Max 50mA either in booting up or  normally working, Continuously working for 30 hours

RS232 Interface (Optional): The data stored in the meter are  uploaded to the computer through RS232 interface and data wire, Then  generate report files

Accessories: Meter: 1 piece, Test ring: 1 Piece,  Meter Suitcase: 1 Piece