• Display method : 4-digit 7-segment LED Control method : ON/OFF, P, PI, PD, PID
  • Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω
  • Sampling cycle : 100ms
  • Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
  • Power supply : 100-240VAC~ 50/60Hz
  • ※In case of the AC voltage model, SSR drive output method (standard ON/OFF control, cycle control, phase control) is available to select. ※Display accuracy: At room temperature (23℃ ±5℃) Thermocouple R (PR), S (PR), below 200℃: (PV ±0.5% or ±3℃, select the higher one) ±1-digit Thermocouple R (PR), S (PR), over 200℃: (PV ±0.5% or ±2℃, select the higher one) ±1-digit Thermocouple L (IC), RTD Cu50Ω: (PV ±0.5% or ±2℃, select the higher one) ±1-digit
  • Out of room temperature range Thermocouple R (PR), S (PR), below 200℃: (PV ±1.0% or ±6℃, select the higher one) ±1-digit Thermocouple R (PR), S (PR), over 200℃: (PV ±0.5% or ±5℃, select the higher one ±1-digit Thermocouple L (IC), RTD Cu50Ω: (PV ±0.5% or ±3℃, select the higher one) ±1-digit For TCN4S-□-P, add ±1℃ by accuracy standard.
  • Display method 4-digit 7-segment LED Control method ON/OFF, P, PI, PD, PID Input specification Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω Sampling cycle 100ms