Igniter KP772 gas burner infrared burner ignition high pressure gauge controller
1PC
KP772 Japanese igniter
Specifications: AC220V, 50/60HZ Output voltage: 15KV
Ambient temperature: -10℃~60℃ Weight: 480g
Gas infrared burner automatic ignition, safety control system
Automatic ignition of various fire row burners, safety control system
Automatic ignition of various small gas burners, safety control system
Small tubular boiler automatic ignition, safety control system;
Ignition output, S signal induction,
Green: Power 22OV, Blue: Neutral (N)
Orange and blue: PV gas solenoid valve, white and blue: L1 flameout (ignition) indicator
Red and blue: L2 burning (working) indicator light, yellow and blue: BZ siren, black: ground wire
The input voltage is 220V-240V, and the output high voltage is above 16KV, the current is 0.8A, and the power is 2W. When the ignition is working normally (the red light is on), it can automatically re-ignite when the flame is turned off during normal use. When the ignition time (22 seconds) is exceeded, the gas solenoid valve will be automatically closed and an alarm will sound.