Digital Multimeter Tester 2000 Counts with DC AC Voltmeter and Ohm Volt Amp Meter; Measures Voltage, Current, Resistance, Continuity and Diode, Blue

fortknoxi-0

Digital Multimeter Tester 2000 Counts with DC AC Voltmeter and Ohm Volt Amp Meter; Measures Voltage, Current, Resistance, Continuity and Diode, Blue


Product description

  • Why does my multimeter not show results?

    1) The plugs of test leads are not fully inserted or not inserted into the correct sockets. Please refer to the manual to reinsert them. 2) Please make sure the dial is set to the correct range.

  • What should I do if this item does not work?

    Incorrect testing may have caused the fuse to blow. Please replace it with new fuses.

  • Does it work for Low voltage?

    Note: This multimeter can not measure AC voltage below 100mV. It does not apply to scenarios such as body voltage.

AstroAI Multimeter Series

Add to Cart
Add to Cart
Add to Cart
Add to Cart
Customer Reviews
4.5 out of 5 stars 53,355
4.7 out of 5 stars 616
4.6 out of 5 stars 7,284
4.6 out of 5 stars 19,772
4.6 out of 5 stars 1,414
4.6 out of 5 stars 11,652
4.2 out of 5 stars 104
Price
$14.59$14.59 $9.99$9.99 $17.99$17.99 $33.99$33.99 $36.54$36.54 $79.99$79.99 $39.99$39.99
Maximum Display
2000 Counts 2000 Counts 4000 Counts 6000 Counts 10000 Counts & Carrying case 6000 Counts 20000 Counts & Carrying case
Range Selection
Manual Manual Auto Manual and Auto Manual and Smart Auto Manual and Auto Auto
AC/DC Voltage
AC 750v / DC 1000v 750V AC /1000V DC DC V Accuracy: ±(0.08% + 5)
AC/DC Current
Only DC Current 1000A AC/DC
Resistance/Continuity
Diode
Capacitance/Frequency
X X Only Capacitance
Temperature
X X X
Inrush
X X X X X X
VFD / LoZ
X X X X X X

Specifications

Environmental Conditions CAT II 600 V; CAT Ill 300 V
Pollution Level 2
Temperature and Humidity 32-104 ° F (0-40 °C);(<80% RH, <10 °C RH)
Range Selection Manual
Fuse Protection mA: F250 mA/250 V Fuse;10 A: F10 A/250 V Fuse
Sample Speed 3 Times Per Second
Digital Display 2000 Counts. The unit symbols will automatically appear according to the measured functions
Overload Indication "OL" Displayed
Power 2 x 1.5 V AAA Batteries
DC Voltage 200mV/2V/20V/200V/600V ±(0.5%+3)
AC Voltage 200V/600V ±(0.8%+5)
DC Current 200µA/200mA/10A ±(1.2% +3)
Resistance 200Ω/2KΩ/20KΩ/200KΩ ±(1.0%+3);20MΩ ±(1.5%+3)

Fulfillment Notice: We utilize multiple U.S. distribution centers and logistics partners to ensure fast and reliable delivery. Packaging may vary depending on the shipping location.

fortknoxi-0