Fluke 18B+ Plus AC DC Voltage Current Digital Multimeter DMM with LED
|
|
Feature:
Fast Response
Greater capacitance range: 0.01nF ~ 1000?F
The more bright: Add white LED backlight
Larger screen: Larger than the original 1.5 times
Frequency & duty cycle
Auto/Manual range
Max/Min value
600 V CAT III 1000V CAT.II
Specifications:
|
Display
|
4000counts
|
|
LED test
|
Yes
|
|
Auto/Manual range
|
Yes
|
|
Data hold
|
Yes
|
|
Diode test
|
Yes
|
|
Continuity
|
Yes
|
|
Auto power off
|
Yes
|
|
Specifications
|
|
Function
|
Range
|
Accuracy
|
|
Voltage DC
|
0.1mV~1000V
|
± (1.0%+3)
|
|
Voltage AC(40Hz~500Hz)
|
0.1mV~1000V
|
± (1.0%+3)
|
|
Current AC(40Hz~200Hz)
|
0.1uA~10A
|
± (1.5%+3)
|
|
Current DC
|
0.1uA~10A
|
± (1.5%+3)
|
|
Resistance
|
0.1?~40M?
|
± (0.5%+2)
|
|
Capacitance
|
0.01nF~100uF
|
± (2.0%+5)
|
|
LED test
|
2~6V DC
|
10%
|
|
Mechanical & General Specifications
|
|
Size
|
180 x 89 x 51.5 mm
|
|
Weight
|
425g (battery included)
|
|
Battery
|
2x AA 1.5V
|
|
CAT class
|
CAT.III 600V CAT.II 1000V
|
|
Function
|
Range
|
Resolution
|
Accuracy
|
|
15B+
|
17B+
|
18B+
|
|
AC Volts
(40Hz-500Hz)[1]
|
4.000V
40.00V
400.0V
1000V
|
0.001V
0.01V
0.1V
1V
|
1.0 % + 3
|
1.0 % + 3
|
1.0 % + 3
|
|
AC Millivolts
|
400.0mV
|
0.1mV
|
3.0 % + 3
|
3.0 % + 3
|
3.0 % + 3
|
|
DC Millivolts
|
400.0mV
|
0.1mV
|
1.0 % + 10
|
1.0 % + 10
|
1.0 % + 10
|
|
DC volts
|
4.000V
40.00V
400.0V
1000V
|
0.001V
0.01V
0.1V
1V
|
0.5 % + 3
|
0.5 % + 3
|
1.0 % + 3
|
|
[1]All ac, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
|
|
Function
|
Range
|
Resolution
|
Accuracy
|
|
15B+
|
17B+
|
18B+
|
|
AC Current ?A
(40 Hz-400Hz)
|
400.0 ?A
4000 ?A
|
0.1 ?A
1 ?A
|
1.5 % + 3
|
1.5 % + 3
|
1.5 % + 3
|
|
AC current Ma
(40Hz ? 400Hz)
|
40.00 m
400.0 mA
|
0.01 mA
0.1 mA
|
1.5 % + 3
|
1.5 % + 3
|
1.5 % + 3
|
|
AC current A[1]
(40Hz ? 400Hz)
|
4.000 A
10.00 A
|
0.001 A
0.01 A
|
1.5 % + 3
|
1.5 % + 3
|
1.5 % + 3
|
|
DC current ?A
|
400.0 ?A
4000 ?A
|
0.1 ?A
1 ?A
|
1.5 % + 3
|
1.5 % + 3
|
1.5 % + 3
|
|
DC current mA
|
40.00 mA
400.0 mA
|
0.01 mA
0.1 mA
|
1.5 % + 3
|
1.5 % + 3
|
1.5 % + 3
|
|
DC current A[1]
|
4.000 A
10.00 A
|
0.001 A
0.01 A
|
1.5 % + 3
|
1.5 % + 3
|
1.5 % + 3
|
|
[1] 10 A duty cycle < minutes on, 20 minutes off.
|
Diode Test, Temperature, Resistance, Capacitance, Frequency, and Duty Cycle
|
Function
|
Range
|
Resolution
|
Accuracy
|
|
15B+
|
17B+
|
18B+
|
|
Diode Test[1]
|
2.000V
|
0.001V
|
10 %
|
|
Temperature
|
50.0°C-400.0°C
0°C-50.0°C
-55.0°C -0°C
|
0.1°C
|
NA
|
2 % +1°C
2°C
9% +2°C
|
NA
|
| |
|
|
|
|
|
|
Resistance
(Ohms)
|
400.0?
4.000K?
40.00K?
400.0K?
4.000M?
40.00M?
|
0.1?
0.001K?
0.01K?
0.1K?
0.001M?
0.01M?
|
0.5%+3
0.5%+2
0.5%+2
0.5%+2
0.5%+2
1.5%+3
|
0.5%+3
0.5%+2
0.5%+2
0.5%+2
0.5%+2
1.5%+3
|
0.5%+3
0.5%+2
0.5%+2
0.5%+2
0.5%+2
1.5%+3
|
|
Capacitance[2]
|
40.00 nF
400.0 nF
4.000 ?F
40.00 ?F
400.0 ?F
1000 ?F
|
0.01 nF
0.1 nF
0.001?F
0.01?F
0.1?F
1?F
|
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
|
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
|
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
|
|
Frequency[3]
(10Hz -100kHz)
Hz
|
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
|
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
|
NA
|
0.1%+3
|
0.1%+3
|
|
Duty Cycle[2]
|
1% to 99%
|
0.1 %
|
NA
|
1%typical[4]
|
1% typical[4]
|
|
[1] Typically, open circuit test voltage is 2.0 V and short circuit is <0.6 mA
[2] Specifications do not include errors due to test lead capacitance and capacitance floor(may be up to 1.5nF in the 40 nF range).
[3] All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. In puts below 1 % of range are not specified.
[4] Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90 %.
|
LED Test and Continuity Threshold
|
Function
|
Lighting Range
|
Measurement Range
|
Resolution
|
Accuracy
|
|
LED VF Test[1]
(LED Test Socket)
|
1.00 to 6.00 V
|
NA
|
NA
|
NA
|
|
LED VF Test[2]
( Test leads)
|
1.00 to 6.00V
|
1.00 to 6.00V
|
0.01V
|
10%[3]
|
|
Continuity Threshold
|
NA
|
NA
|
NA
|
NA
|
|
[1] Open circuit test voltage is±12V and short-circuit current is<±5mA(typical)
[2] Open circuit test voltage is±12V and short-circuit current is<±3mA(typical)
[3] VF Measurement with driving current under2.2±0.4 mA
|
Input Characteristics
|
Function
|
Overload Protection
|
Input Impedance
(Nominal)
|
Common Mode
Rejection Ratio
|
Normal Mode
Rejection Ratio
|
|
AC Volts
|
1000V[1]
|
>10M?,<pF
|
>60 dB at dc,
50Hz or 60Hz
|
_
|
|
AC Millivolts
|
400mV
|
>1M?,<100pF
|
>80dB at dc,
50Hz or 60 Hz
|
_
|
|
DC Volts
|
1000V[1]
|
>10M?,<100pF
|
>100dB at dc,
50Hz or 60 Hz
|
>60dB at
50Hz or 60 Hz
|
|
DC Millivolts
|
400mV
|
>1M?,<100pF
|
>80dB at ac,
50 Hz or Hz
|
_
|
|
[1]106V Hz Max
|
Closer Look:
Package Includes:
1 x Fluke 18B+ Multimeter
1 x A Pair of Original Test leads
1 x User manual (English Manual in PDF file Format)
|
| Payment |
- We accept both Paypal and Credit card (what no Paypal account needed). They are easy and safety what you need is only a credit card.
- Please make payment within 5 days when you bid or auction ended.
- Please DO NOT bid if you are NOT intend to buy. For unpaid item more than 5 days, Unpaid dispute & the Negative Feedback will be filed to eBay for the non payable bidders.
|
| Shipping & Delivery |
- All products will be sent within 48 hours after your Paymet received except Sunday (GMT+8).
|
| Contact Us |
- Welcome!! Please read ALL POLICIES of us before your purchase.
- If you have additional questions or concerns about this item, please contact us via email. We will response the most E-mail within 24hours(9:00-18:00 GMT+8 Monday-Friday).
- They Message through eBay could be marked as Spam sometimes. Please check Spam folder of your Email Box first, if you haven't received our response after 72 hours.
|
| Return Policy |
- If the item is defective, please notify us within 7 days after the receipt of the item.
- The item shall be return in its original condition, in order to get it refunded or replaced.
|
| Feedback |
- You will get a POSITIVE FEEDBACK after you paid.
- Your satisfaction and FEEDBACK is VERY important to us. If you have questions regarding your order, or if you feel that have a problem with order, please contact us for a resolution before leaving feedback. We appreciate the opportunity to have a fair transaction.
|
|
|
|