The 501/421 dual certified Exe/Exd cable gland is intended for use on non-armoured elastomer and plastic insulated cables. This cable gland may be used with braided cables where the braid and outer sheath pass into the enclosure. For Exd application the cable must be suitable inline with 60079-14. The braid must then be suitably terminated inside the enclosureSee technical section for installation rules and regulations

  • Elastomeric Exd flameproof seal on cable inner sheath
  • Rounded Cable entry to prevent cable damage

See technical section of the datasheet for installation rules and regulations. Visit www.universalreloaded.com to download a full version of the catalogue




General

ApplicationSuitable for use in Zone 1, Zone 2, Zone 21 and Zone 22
Ingress ProtectionIP66, IP67 and IP68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X
MaterialBrass, NP Brass or Stainless Steel
Operating Temperature-60°C to +100 °C
SeriesGroup II Cable Glands

Certifications and Compliance

ATEX File NumberCML 19ATEX1167XCML 19.0045X
CSA File NumberCSA1015065