Description
The Progressive Industries EMS-LCHW50 is a 50-amp, 120/240V hardwired Electrical Management System (EMS) designed to provide comprehensive, permanent protection for RV electronics against voltage fluctuations, surges, and faulty power pedestals. It boasts 3,580 Joules of surge protection, detects faults like low/high voltage, open neutral, and reverse polarity. A digital display provides real-time monitoring and error code history.
Features
- EMS automatically shuts down power whenever AC power falls below 104 volts, or rises above 132 volts.
- If AC power is interrupted, or the EMS detects a fault condition, the built-in time delay is activated to accommodate the heavy air conditioner start-up load.
- Full surge protection L-N, L-N, L-G, L-L and N-G within <1 nano second
- Total Joule rating of 3,580, 88,000A surge current.
- Digital display for easy troubleshooting.
- In a reverse polarity condition the EMS will not allow power to the RV and the error code will show in the display.
- If there is an open neutral condition the display will not light and the EMS will not allow power to the RV.
- If there is an open ground condition the EMS will read an error code and power will not be allowed to the RV.
- If AC power frequency deviates +/- 9 hertz from 60 cycles per second, the EMS will shut down power and an error code will be displayed.
- If 240 volts is detected the EMS shuts off power instantly not allowing power to the RV and the display will read the voltage and error code.
- Display continuously scrolls voltage, current, frequency, error codes and previous errors displaying each for 2 seconds.
- Previous error indicates why power was interrupted to the RV. The error is deleted when power is disconnected from the EMS.
- Replacement parts are designed for simple plug and play, making repairs extremely user friendly.
- State-of-the-art microprocessor that is programmed with software to drive the entire EMS.
Specifications
Amperage/Voltage: 50 Amps / 120V-240V AC.
Surge Protection Rating: 3,580 Joules (88,000A maximum surge current).
Dimensions: Approximately 10.2" L x 4.8" W.
Protection Features: Open neutral, open ground, reverse polarity, accidental 240V, and surge failure protection.
Display: Integrated scrolling digital display for diagnostics.
Time Delay: User-selectable 15-second or 136-second (default 15s) for A/C units.
Material: Polycarbonate enclosure.
FREE SHIPPING
NOTE: Regardless of the buyer's indicated preference for carrier, we will utilize whichever carrier quotes the lowest cost as long as the delivery time is the same or better than that quoted by the other carriers. If there is a critical need to use a specific carrier please contact us and share the reason for the need and we will gladly work with you to address your specific need.
*PLEASE NOTE*
Our highest priority is ensuring customer satisfaction with our products and service. If for any reason we do not meet this standard, we will diligently work to provide a prompt resolution. In the very unlikely event you find this item to be other than described, please contact us before submitting a request for return to ebay. Contacting us before ebay will ensure a quicker resolution of any issue to your full satisfaction. Simply send us a message and we will respond (within a few hours at most) with a full resolution shortly thereafter.