220V 8'' Cylinder Pipe Fan
|
| |
| |
| |
 |
| Product Overview |
| The powerful cylindrical pipe exhaust fan is a high-quality ventilation device, is suitable for the commercial and industrial environments, and is designed for ventilation, heat dissipation and air exchange of various working places. The exhaust fan has the high air volume of 1300m³/h, high strength, 8in compact structure, high durability and moderate noise of ≥46dB, and is an optimum product for customers. |
| Product Parameters |
| Voltage |
220V Single-phase electricity |
| Power |
80W |
| Maximum load power |
90W |
| Size |
8in |
| Air volume |
1300m³/H |
| Diameter of inner circle |
21.5cm (8.46in) |
| Diameter of outer circle |
26.5cm (10.43in) |
| Shape thickness |
20cm (7.87in) |
| Noise |
≥46dB |
| Speed |
1400r/min |
|
 |
| Installation and Use |
 |
|
1. When the fan is installed, the horizontality and the perpendicularity of the fan need to be adjusted to ensure the stable operation of the fan blade.
2. After the fan is fixed, the remaining space must be sealed.
3. If the fan needs to be connected with a pipeline, please remove the protective net by yourself.
|
|
| |
 |
|
1. The lines of the fans in different batches will be different in color. The color of the ground line is unchanged and is yellow green.
2. When wiring is conducted, the ground line is connected with the ground wire (or is not connected with the ground wire), and the other two lines can be connected with other wires.
3. The length of the wire for the fan is about 30cm. If you need to extend it, please purchase it by yourself.
|
|
| |
 |
|
Pay attention to the air flow direction during installation and use. |
|
| Attention |
| 1. During installation and cleaning of the fan, do not bump, press or arbitrarily change the angle of the fan blades. |
| 2. Do not clean the motor cable with water to prevent leakage. Never use thinner, gasoline or other liquids that corrode plastic and painted parts. |
| 3. Do not use the fan in places with acidic, alkaline or explosive gases. |
| 4. After 1500 hours of operation, the bearing lubricating grease should be replaced. |
| 5. The fan must be properly grounded. Effective grounding can prevent electric shock accidents caused by leakage and protect the safety of operators. |
| 6. Be sure to disconnect the power supply before maintenance, cleaning and component replacement of the fan. |
| 7. Do not operate the fan beyond its rated operating conditions. |
| 8. Keep a safe distance around the fan during operation. Do not place hands, tools or other objects near the rotating fan blades to avoid personal injury. |
| 9. Let a professional electrician conduct wiring, installation, repair and maintenance of the fan. |
| Product Features |
|
|
| The 4-leaf type stainless steel fan blade is designed for the exhaust fan and is of a large-angle spiral structure, the suction is more powerful, and the noise is lower. The fan blade has the resistance to rust and oil stains, high in strength and longer in service life, and is not prone to breakage. |
|
The shell of the exhaust fan is made of thickened iron materials, and therefore the shell has the high firmness, high stability and high durability and is not prone to deformation. The shell is subjected to advanced baking finish treatment, so that it is resistant to greasy dirt and wear, can be kept clean and smooth for a long time and is attractive and practical. |
|
| |
|
|
| The exhaust fan is equipped with an upgraded pure copper double ball bearing motor with the 80W power and the maximum load power of 90W, the high driving force can be provided for the fan, and the motor adopts thickened coils to ensure the longer service life, and well achieves energy saving and noise reduction. |
|
The cylinder pipe fan is equipped with a detachable protective net which can effectively prevent the body and other things from entering the fan, so that the damage risk is effectively reduced, and the personal injury is well avoided. The airflow efficiency can be optimized, and the detachable design facilitates cleaning and maintenance. |
|
| Operation Method |
| 1. Before use, check whether the relevant electrical parameters on the fan are matched with the power supply to avoid burnout. The insulation resistance of the fan head winding to the ground should be greater than 0.5 megohm before use. |
| 2. Before operation, manually rotate the fan blades to ensure that there is no deformation or collision with the frame. |
| 3. Let a professional electrician connect the wire of the fan to the power supply. |
| 4. After the fan is powered on, be sure to check the rotation direction of the fan blades. The correct rotation direction is that when viewed from the front of the fan blade, the blade rotate counterclockwise. If the rotation direction is incorrect, contact the seller to replace it to avoid accidents. |
| 5. After using the fan for a long time, disconnect the power supply, disassemble the fan and clean it with cotton cloth dipped in the appropriate cleaning agent. |
| Application |
| As an excellent ventilation device, the cylinder pipe fan has high product quality and high using performance and can be widely used for ventilation and heat dissipation in factories, workshops, warehouses and other industrial places, for exhaust of cooking fumes and stream in restaurant kitchens, canteen kitchens and other large kitchens, for air circulation and air exchange in supermarkets, shopping malls, restaurants and other crowded places, and for odor removal in farms, breeding bases and other livestock breeding places. |
 |
| Product Display |
.jpg) |
.jpg) |
.jpg) |
.jpg) |
| Item Number (022039): 1 x Cylinder Pipe Fan 220V 8'' |
| |
|
|