Schneider GV2RT21 MANUAL STARTER 600V 23A, NEW

 

NEW IN BOX.


TeSys GV motor circuit breaker, 3 poles (3P), 23A/690V, for high starting current peak motor applications 9-11kW@400V. It provides a thermal-magnetic protection with a thermal setting range 17-23A, a magnetic tripping level at 17xIn, high breaking capacity Icu 15kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

 

Range

TeSys Deca

Product name

TeSys GV2
TeSys Deca

Product or component type

Motor circuit breaker

Device short name

GV2RT

Device application

Motor protection

Trip unit technology

Thermal-magnetic

 

Complementary

Poles description

3P

Network type

AC

Utilisation category

Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1

Network frequency

50/60 Hz conforming to IEC 60947-4-1

Fixing mode

35 mm symmetrical DIN rail: clipped
Panel: screwed (with adaptor plate)

Motor power kW

5.5 kW at 220/230 V AC 50/60 Hz motor protection high peak current
9 kW at 400/415 V AC 50/60 Hz motor protection high peak current
11 kW at 400/415 V AC 50/60 Hz motor protection high peak current
11 kW at 440 V AC 50/60 Hz motor protection high peak current
11 kW at 500 V AC 50/60 Hz motor protection high peak current
18.5 kW at 690 V AC 50/60 Hz motor protection high peak current

Breaking capacity

50 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
4 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2

Control type

Toggle

[In] rated current

23 A

Thermal protection adjustment range

17…23 A conforming to IEC 60947-4-1

Magnetic tripping current

400 A

[Ith] conventional free air thermal current

23 A conforming to IEC 60947-4-1

[Ue] rated operational voltage

690 V AC 50/60 Hz conforming to IEC 60947-2

[Ui] rated insulation voltage

690 V AC 50/60 Hz conforming to IEC 60947-2

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947-2

Suitability for isolation

Yes conforming to IEC 60947-1 § 7-1-6

Power dissipation per pole

2.5 W

Mechanical durability

100000 cycles

Electrical durability

100000 cycles for AC-3 at 415 V In
100000 cycles for AC-3e at 415 V In

Rated duty

Continuous conforming to IEC 60947-4-1

Tightening torque

1.7 N.m - on screw clamp terminal

Width

45 mm

height

89 mm

Depth

78.5 mm

 

Environment

Standards

EN/IEC 60947-2
EN/IEC 60947-4-1

product certifications

CCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
UKCA

IK degree of protection

IK04

IP degree of protection

IP20 conforming to IEC 60529

Climatic withstand

Conforming to IACS E10

Ambient air temperature for storage

-40…80 °C

Fire resistance

960 °C conforming to IEC 60695-2-11

Ambient air temperature for operation

-20…60 °C

Mechanical robustness

Shocks: 30 Gn for 11 ms
Vibrations: 5 Gn, 5...150 Hz

Operating altitude

2000 m

 

 