| Number of inputs and outputs | Number of analogue outputs: 1 |
|---|---|
| Process connection | G 1 external thread Aseptoflex Vario |
| Special feature | Gold-plated contacts | |||
|---|---|---|---|---|
| Media | conductive liquids | |||
| Note on media |
| |||
| Cannot be used for | See the operating instructions, chapter "Function and features". | |||
| Medium temperature [°C] | -25...100; (< 1 h: 150) | |||
| Pressure rating [bar] | 16 | |||
| Vacuum resistance [mbar] | -1000 |
| Operating voltage [V] | 18...30 DC | |
|---|---|---|
| Current consumption [mA] | < 50 | |
| Protection class | III | |
| Reverse polarity protection | yes | |
| Power-on delay time [s] | 2 | |
| Measuring principle | inductive |
| Total number of outputs | 1 |
|---|---|
| Output signal | analogue signal; IO-Link |
| Output function | analogue output; scalable; selectable conductivity / temperature |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4...20 |
| Max. load [Ω] | 500 |
| Measuring range [µS/cm] | 100...1000000 | ||||||
|---|---|---|---|---|---|---|---|
| Resolution [µS/cm] |
|
| Accuracy (in the measuring range) | 2 % MW ± 25 µS/cm |
|---|---|
| Drift [%/K] | 0,1 %/K MW ± 25 µS/cm |
| Repeatability | 1 % MW ± 25 µS/cm |
| Long-term stability | 0,5 % MW ± 25 µS/cm |
| Measuring range [°C] | -25...150 |
|---|