Description:Sensing InpuuutVoltage 220 / 380 / 440 VAC, 1 phase2 wireDIP switch selectableFrequency 50 / 60 Hz, DIP switch selectablePower InputVoltage 100 ~ 300 VAC, 1 phase 2 wireOutputVoltage Max. 90 VDC @ 240 VAC inputCurrent Continuous 5AIntermittent 7A for 10 secResistance Min. 15 ohm Max. 100 ohmVoltage Regulation< ± 0.5% ( with 4% engine governing )Voltage Build-upResidual voltage at AVR terminal > 5 VACThermal Drift0.03% per °C change in AVR ambientExternal Volts Adjustmen± 7% with 1K ohm 1 watt trimmerEMI SuppressionInternal electromagnetic interference filteringUnit Power DissipationMax. 8 wattUnder Frequency Protection (Factory Setting)60 Hz system presets knee point at 55 Hz50 Hz system presets knee point at 45 HzSoft Sta...
New AVR EA05A Automatic Voltage Regulator Controller For Generator Genset Parts

Description:
Sensing Inpuuut
Voltage 220 / 380 / 440 VAC, 1 phase2 wire
DIP switch selectable
Frequency 50 / 60 Hz, DIP switch selectable
Power Input
Voltage 100 ~ 300 VAC, 1 phase 2 wire
Output
Voltage Max. 90 VDC @ 240 VAC input
Current Continuous 5A
Intermittent 7A for 10 sec
Resistance Min. 15 ohm Max. 100 ohm
Voltage Regulation
< ± 0.5% ( with 4% engine governing )
Voltage Build-up
Residual voltage at AVR terminal > 5 VAC
Thermal Drift
0.03% per °C change in AVR ambient
External Volts Adjustmen
± 7% with 1K ohm 1 watt trimmer
EMI Suppression
Internal electromagnetic interference filtering
Unit Power Dissipation
Max. 8 watt
Under Frequency Protection (Factory Setting)
60 Hz system presets knee point at 55 Hz
50 Hz system presets knee point at 45 Hz
Soft Start Ramp Time
3 sec.
Dimensions
101mm L * 69mm W * 47.5mm H
Weight
183g ± 2%
2. WIRING
When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance.
EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”.
1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together (as show as figure3. It’s the original setting).or connect independent.(as show as figure2).
2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC.
3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless.
P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。
C above 600V.
The EXT.VR connection wires must be made of isolated wiring.
3. ADJUSTMENTS
The voltage setting for 220V/380V/440V and the
frequency setting for 50/60HZ is show in figure7.
Please check the voltage/frequency selector setting
is correct before start the generator.

 

CAUTION :
THE GENERATOR OR AVR MAY BE DAMAGED
IF THE VOLTAGE / FREQUENCY SELECTOR
SETTING IS INCORRECT.
UFRO DIP:
Close - please refer to solid curre in Figure8.
Open - please refer to dotted curre in Figure8.
1. Before you turn on the generator, please turn the
voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.)
2. Adjust “Stability Adjustment” clockwise slowly to
change the feedback time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you
just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate.
4. FIELD FLASHING
When the regulator is operated with the generator for
the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps :
1. With the Prime-mover at rest and the regulator’s
field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.)
2. Allow approximately 3 seconds before removing
the DC source.
3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure.
4. If repeating steps a. and b. does not result in
generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator.

 

Package Include:
1 x Automatic Voltage Regulator Controller AVR EA05A Genset Parts
1 x product Instructions

 


Payment

We accept Paypal ,Google pay, Visa,Master Card, American Express, Discover.eBay Mastercard etc.

Shipping

We process and dispatch your purchase within 1 business day after payment clearance.

For weekend orders, we will deliver the goods on Monday

Returns

Please contact us first when return, exchange and refund is required. Any direct return of purchased items will not be processed.
We will closely examine the condition of the returned items and will not issue any refund/exchange before we make sure the items are in their original neat conditions.

Contact Us

Before leaving us neutral or negative feedback, please contact us first.
We will do everything we can to give you a satisfying solution.
Please don't open case via ebay or paypal.
Please don't open any return request before contact us.
We do our best to resolve any issue. Leaving negative feedbacks and low ratings doesn't get things solved.
So please talk with us and we will not let you down.

FAQ

How much does delivery cost and how long will it take?
You can check the delivery cost in the listing “Shipping and payments” section by selecting your country and entering your zip code. If it is not specified, please provide us your shipping address and zip code via eBay message.
 
What payment methods do you accept?
We currently only accept payment via PayPal.
 
When will my order be dispatched?
We will arrange the shipment in 1 business day after the payment is cleared. The tracking number will be updated on eBay in 24 hours after the shipment. Please notice that there is no shipment during weekend and holidays.
 
 
What do I do if I have not received my order?
Please simply contact us via eBay messages, and then, we will get back to you as soon as possible with the update. Usually, we will follow up every shipment till customers get their order.
 
What do I do if my product is faulty?
Please simply contact us via eBay messages, and then, we will get back to you as soon as possible. It will speed up the process if you could provide us some pictures or video to illustrate the issue details.

New AVR EA05A Automatic Voltage Regulator Controller For Generator Genset Parts

Description:
Sensing Inpuuut
Voltage 220 / 380 / 440 VAC, 1 phase2 wire
DIP switch selectable
Frequency 50 / 60 Hz, DIP switch selectable
Power Input
Voltage 100 ~ 300 VAC, 1 phase 2 wire
Output
Voltage Max. 90 VDC @ 240 VAC input
Current Continuous 5A
Intermittent 7A for 10 sec
Resistance Min. 15 ohm Max. 100 ohm
Voltage Regulation
< ± 0.5% ( with 4% engine governing )
Voltage Build-up
Residual voltage at AVR terminal > 5 VAC
Thermal Drift
0.03% per °C change in AVR ambient
External Volts Adjustmen
± 7% with 1K ohm 1 watt trimmer
EMI Suppression
Internal electromagnetic interference filtering
Unit Power Dissipation
Max. 8 watt
Under Frequency Protection (Factory Setting)
60 Hz system presets knee point at 55 Hz
50 Hz system presets knee point at 45 Hz
Soft Start Ramp Time
3 sec.
Dimensions
101mm L * 69mm W * 47.5mm H
Weight
183g ± 2%
2. WIRING
When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance.
EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”.
1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together (as show as figure3. It’s the original setting).or connect independent.(as show as figure2).
2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC.
3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless.
P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。
C above 600V.
The EXT.VR connection wires must be made of isolated wiring.
3. ADJUSTMENTS
The voltage setting for 220V/380V/440V and the
frequency setting for 50/60HZ is show in figure7.
Please check the voltage/frequency selector setting
is correct before start the generator.

 

CAUTION :
THE GENERATOR OR AVR MAY BE DAMAGED
IF THE VOLTAGE / FREQUENCY SELECTOR
SETTING IS INCORRECT.
UFRO DIP:
Close - please refer to solid curre in Figure8.
Open - please refer to dotted curre in Figure8.
1. Before you turn on the generator, please turn the
voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.)
2. Adjust “Stability Adjustment” clockwise slowly to
change the feedback time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you
just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate.
4. FIELD FLASHING
When the regulator is operated with the generator for
the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps :
1. With the Prime-mover at rest and the regulator’s
field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.)
2. Allow approximately 3 seconds before removing
the DC source.
3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure.
4. If repeating steps a. and b. does not result in
generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator.

 

Package Include:
1 x Automatic Voltage Regulator Controller AVR EA05A Genset Parts
1 x product Instructions

 



We accept Paypal ,Google pay, Visa,Master Card, American Express, Discover.eBay Mastercard etc.

We process and dispatch your purchase within 1 business day after payment clearance.

For weekend orders, we will deliver the goods on Monday

Please contact us first when return, exchange and refund is required. Any direct return of purchased items will not be processed.
We will closely examine the condition of the returned items and will not issue any refund/exchange before we make sure the items are in their original neat conditions.

Before leaving us neutral or negative feedback, please contact us first.
We will do everything we can to give you a satisfying solution.
Please don't open case via ebay or paypal.
Please don't open any return request before contact us.
We do our best to resolve any issue. Leaving negative feedbacks and low ratings doesn't get things solved.
So please talk with us and we will not let you down.

How much does delivery cost and how long will it take?
You can check the delivery cost in the listing “Shipping and payments” section by selecting your country and entering your zip code. If it is not specified, please provide us your shipping address and zip code via eBay message.
 
What payment methods do you accept?
We currently only accept payment via PayPal.
 
When will my order be dispatched?
We will arrange the shipment in 1 business day after the payment is cleared. The tracking number will be updated on eBay in 24 hours after the shipment. Please notice that there is no shipment during weekend and holidays.
 
 
What do I do if I have not received my order?
Please simply contact us via eBay messages, and then, we will get back to you as soon as possible with the update. Usually, we will follow up every shipment till customers get their order.
 
What do I do if my product is faulty?
Please simply contact us via eBay messages, and then, we will get back to you as soon as possible. It will speed up the process if you could provide us some pictures or video to illustrate the issue details.


All rights reserved.



On Apr 17, 2026 at 03:45:26 PDT, seller added the following information:

Datacaciques