174627.00, LEESON, 10 HP, 400-480V, 3PH, NEMA 1, SM2,DRIVE FRÉQUENCY
174627.00, LEESON, VARIABLE FREQUENCY DRIVE, LEESON SM2 SERIES FLUX VECTOR carries all the features required by demanding applications including four modes of operation (V/Hz, Enhanced V/Hz, Vector Speed, and Torque), High starting torque, auto-tuning, advanced low-speed control, and dynamic speed regulation. Enclosure: NEMA1, IP21, -10 to 55*C, 2.5% derate per *C above 40*C Standard Features: Easy Set-up and Operation: Program the Vector control in one of four convenient ways: From the front of the drive The optional remote keypad A PC Using TechLink Software The innovative EPM Programmer. Modes of operation: Open Loop Flux Vector (Speed or Torque) V/Hz (constant or variable) Enhanced V/Hz with Auto-tuning Easy to Use Keypad & Display 6-Button Interface: Start Stop Forward/Reverse Scroll Up Scroll Down Enter/Mode Vivid Illumination: 4 digit LED display Easy to read from a distance Movable Decimal Point Acceleration/Deceleration Profiles: Two Independent Accel Ramps Two Independent Decel Ramps Linear or S-Type Auxiliary Ramp-to-Stop Output Frequency: 500 Hz Std., 1000 Hz Optional Selectable Logic Assertion: Positive Logic Input (PNP current sourcing) Negative Logic Input (NPN current sinking) Multiple Braking Functions Loss of Follower Management Speed Commands: Keypad, Jog, Floating Point Control Voltage: Scalable 0-10 VDC Current: Scalable 4-20mA, Potentiometer, 8 Preset Speeds Process Control: PID Modes: Direct or Reverse Acting, PID Sleep Mode Voltage Monitoring Current Monitoring Real Time Monitoring: 8 register fault history, Software Version Drive Network ID, DC Bus Voltage (V), Motor Voltage (V), Output Current (%) Motor Current (A), Motor Torque (%), Power (kW) Energy Consumption (kWh), Heasink Temperature (*C), 0-10 VDC Input (User Defined, 4-20 mA Input (User Defined) PID Feedback (User Defined), Analog Output (% Load, % Torque, kW), Network Speed (baud rate), Terminal Continuity, Keypad Status, Elapse Run Time (hours), Elapsed Power on Time (hours) Standards: UL (USA) cUL (Canada) CE (Europe) GOST (Russia/Ukraine) C-Tick (Australia/New Zealand) Dimensions H x W x D (inches) 9.83 x 5.12 x 6.3
174627.00, LEESON, 10 HP, 400-480V, 3PH, NEMA 1, SM2,DRIVE FRÉQUENCY
174627.00, LEESON, VARIABLE FREQUENCY DRIVE,
LEESON SM2 SERIES FLUX VECTOR carries all the features required by demanding applications including four modes of operation (V/Hz, Enhanced V/Hz, Vector Speed, and Torque), High starting torque, auto-tuning, advanced low-speed control, and dynamic speed regulation.
Enclosure: NEMA1, IP21, -10 to 55*C, 2.5% derate per *C above 40*C
Standard Features: Easy Set-up and Operation: Program the Vector control in one of four convenient ways:
From the front of the drive
The optional remote keypad
A PC Using TechLink Software
The innovative EPM Programmer.
Modes of operation:
Open Loop Flux Vector (Speed or Torque)
V/Hz (constant or variable)
Enhanced V/Hz with Auto-tuning
Easy to Use Keypad & Display 6-Button Interface:
Start
Stop
Forward/Reverse
Scroll Up
Scroll Down
Enter/Mode
Vivid Illumination:
4 digit LED display
Easy to read from a distance
Movable Decimal Point
Acceleration/Deceleration Profiles:
Two Independent Accel Ramps
Two Independent Decel Ramps
Linear or S-Type
Auxiliary Ramp-to-Stop
Output Frequency:
500 Hz Std., 1000 Hz Optional
Selectable Logic Assertion:
Positive Logic Input (PNP current sourcing)
Negative Logic Input (NPN current sinking)
Multiple Braking Functions
Loss of Follower Management
Speed Commands: Keypad, Jog, Floating Point Control
Process Control: PID Modes: Direct or Reverse Acting, PID Sleep Mode
Voltage Monitoring
Current Monitoring
Real Time Monitoring: 8 register fault history, Software Version Drive Network ID, DC Bus Voltage (V), Motor Voltage (V), Output Current (%) Motor Current (A), Motor Torque (%), Power (kW) Energy Consumption (kWh), Heasink Temperature (*C), 0-10 VDC Input (User Defined, 4-20 mA Input (User Defined) PID Feedback (User Defined), Analog Output (% Load, % Torque, kW), Network Speed (baud rate), Terminal Continuity, Keypad Status, Elapse Run Time (hours), Elapsed Power on Time (hours)