Detailed Description:
| General | Brand | FCARD | Model | FC100 | Specification | Response time | <0.2s | Communication | RS232 (TTL), Weigand 26/34 ,ABA | Card type | EM card , EM compatible card ,EM4100\4102 | Induction Distance | 10~18cm(max to 35cm,meanwhile a special coil &card should be necessary) | Induction Type | card | Power supply | DC5V | Working Temperature | 0~70°C | Working Humidity | no more than 80% | Warranty | Warranty | 24 months | Physical | Dimension (LxWxH mm) | 60*25*10mm(62*27*10 epoxy packaged) | Weight (kg) | 0.01 |
Accessory Antenna:40*35mm
Detail view: 
Pin | Symbol | Description | 1 | ANTENNA1 | To antenna | 2 | SEND | No Connect:send data once Connect to GND:send data constantly. | 3 | CRQ | Card requirement:the module will send the card number if pin 3 get a low level input.if no card ,send 0X000000 | 4 | SEL | Select the Data format No connect:WG Connect to GND:ABA | 5 | BEEP_IN | Control the buzzer from outside.low level will cause a beep. | 6 | BEEP | Connect to buzzer’s minus pin. | 7 | LED_IN | Control the LED from outside. | 8 | LED2 | To red LED’s minus pin. | 9 | LED1 | To green LED’s minus pin. | 10 | RESET | reset | 11 | ANTENNA2 | To antenna | 12 | HOLD(CP) | HOLD in WG or CARD PRESENT in ABA | 13 | WG1(CLK),232 | WG1/CLK/TTL RS232 TX | 14 | WG0(DATA) | WG0/DATA | 15 | GND | GND | 16 | +5V | Power | 17 | 26/34 | Select wg26 or wg34,NC wg26,connedt to GND wg34 | 18 | WG1+ | Opposite WG1/DATA,so as to get a RP data to improve the data’s currency and transfer range. | 19 | WG0+ | Opposite WG0/CLK,so as to get a RP data to improve the data’s currency and transfer range. |
Note:connect the pin4 &pin17 to GND,pin13 will be a TTL RS232 with boud rate 9600. Package: - 5pcs FC100 reader module
- 5pcs Accessory Antenna
More Pictures
TTL RS232 format |  |
Wiegand 26bits Format Interface Wiegand 26bits Format Interface comprises of 26bits data including 24
user bits and 2 parity check bits. The 24 user bits correspond to the
latter 40 user bits in tags.
Bit | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | | PE | D | D | D | D | D | D | D | D | D | D | D | D | D | D | D | D | D | D | D | D | D | D | D | D | PO | | | E | E | E | E | E | E | E | E | E | E | E | E | O | O | O | O | O | O | O | O | O | O | O | O | | | | D40 | D41 | D42 | D43 | D50 | D51 | D52 | D53 | D60 | D61 | D62 | D63 | D70 | D71 | D72 | D73 | D80 | D81 | D82 | D83 | D90 | D91 | D92 | D93 | |
A. PE as even parity check bit and PO as odd parity check bit; B. The bits marked with E go for even parity check and the bits marked with O go for odd parity check; 2.Wiegand 26bits Format Timing  SYMBOL | DESCRIPTION | VALUE( Typ. ) | THD | Sending Start Delay | 0.06ms | TSD | Sending Stop Delay | 2ms | TDW | Data pulse width | 0.4ms | TIW | Data pulse interval width | 2ms |
|