ZOYI UK Official Store

ZOYI P2060 60MHz Oscilloscope Probe

1X / 10X Switchable • Passive Probe • BNC Connector • Adjustable Compensation

UK STOCK 🇬🇧   |   FAST UK DISPATCH 🚚   |   UK WARRANTY 🛡️   |   VAT INVOICE ✓
60MHz Probe Bandwidth 1X / 10X Switchable Attenuation 5.8ns Typical Rise Time BNC Standard Connector

60MHz Passive Oscilloscope Probe for Electronics Testing

The ZOYI P2060 is a 60MHz passive oscilloscope probe with switchable 1X / 10X attenuation, designed for waveform measurement, electronics troubleshooting, circuit development and laboratory testing.

A standard BNC connector makes the P2060 compatible with many digital and analogue oscilloscopes using a conventional 1MΩ BNC input.

The probe includes an adjustable compensation trimmer, removable hook tip and ground connection accessories, allowing it to be matched correctly to the oscilloscope input for improved square-wave response and waveform accuracy.

It is suitable for general-purpose measurements including PCB diagnostics, microcontroller circuits, PWM signals, audio electronics, power-supply troubleshooting, educational experiments and repair work.

Switchable 1X / 10X Attenuation

① 1X Mode Provides maximum signal sensitivity for lower-voltage measurements. The probe presents approximately 1MΩ input resistance when used with a compatible 1MΩ oscilloscope input. ② 10X Mode Attenuates the measured signal by a factor of ten, increases effective input resistance to approximately 10MΩ and reduces loading on many electronic circuits.
Important: When the physical probe switch is set to 10X, set the oscilloscope channel's probe attenuation setting to 10X as well.

If the probe and oscilloscope attenuation settings do not match, displayed voltage measurements can be incorrect by a factor of ten.

Key Features

  • 60MHz Bandwidth: Suitable for a wide range of general electronics, educational and troubleshooting applications.
  • 1X / 10X Switchable: Select direct 1X operation or 10X attenuation using the slide switch on the probe body.
  • Approx. 5.8ns Rise Time: Fast transient response suitable for general-purpose waveform and digital signal testing.
  • 10MΩ Input in 10X Mode: Higher effective input resistance helps reduce loading on the circuit under test.
  • Low-Capacitance 10X Mode: Approximately 14–18pF input capacitance helps reduce probe loading during higher-frequency measurements.
  • Adjustable Compensation: Integrated compensation adjustment allows the probe to be matched to a compatible oscilloscope input.
  • Standard BNC Connector: Compatible with many oscilloscopes using conventional BNC channel inputs.
  • Removable Hook Tip: Spring-loaded hook helps maintain contact with component leads, test points and wires during measurement.
  • Ground Lead: Supplied ground connection provides a convenient reference connection to the circuit under test.
  • Lightweight Probe: Approx. 55g probe weight with an approximately 1.1m cable for comfortable bench use.

Adjustable Probe Compensation

Passive 10X oscilloscope probes should be compensated to match the oscilloscope input before accurate waveform measurements are made.

Connect the probe to the oscilloscope's calibration / compensation square-wave output and adjust the compensation trimmer until the displayed square wave has a flat top without excessive rounding or overshoot.

Waveform Appearance Meaning
Rounded Leading Edge Probe is under-compensated
Excessive Overshoot Probe is over-compensated
Flat Square-Wave Top Probe is correctly compensated
Recommended: Check probe compensation whenever the P2060 is connected to a different oscilloscope or channel.

Probe Electrical Characteristics

Specification P2060
Probe Type Passive Voltage Probe
Bandwidth Up to 60MHz
Attenuation 1X / 10X Switchable
Rise Time Approx. 5.8ns
Input Resistance — 1X Approx. 1MΩ
Input Resistance — 10X Approx. 10MΩ ±2%
Input Capacitance — 10X Approx. 14–18pF
Compensation Adjustable
Connector Standard Male BNC

Probe Input Voltage Limits

Probe Setting Maximum Rated Input
1X 150V RMS CAT II
10X 300V RMS CAT II
Important: The safe measurement voltage is limited by the lowest-rated component in the complete measurement system.

The oscilloscope, probe, accessories and circuit connection must all be suitable for the voltage and measurement category involved.

Never exceed the voltage rating printed on the actual probe supplied or the input rating of the connected oscilloscope.

Standard BNC Oscilloscope Connection

The P2060 uses a conventional male BNC connector and is intended for oscilloscopes with a standard BNC channel input.

It can be used with many compatible digital storage oscilloscopes, analogue oscilloscopes and oscilloscope multimeters that provide a conventional BNC input.

Compatibility: For correct attenuation and compensation, the connected oscilloscope should provide a suitable 1MΩ input and compatible input capacitance.

Ideal Companion for ZOYI Oscilloscopes

The P2060 is suitable for compatible ZOYI instruments fitted with standard BNC oscilloscope inputs, including popular handheld oscilloscope multimeter models.

  • ZOYI ZT-702S
  • ZOYI ZT-703S
  • ZOYI ZT-706S
  • Other compatible 1MΩ BNC oscilloscopes
Always check the oscilloscope's bandwidth, input impedance, probe attenuation and maximum input-voltage specifications before use.

Ground Connection & High-Frequency Measurement

Probe grounding can have a significant effect on waveform quality, particularly when measuring fast digital signals and higher-frequency circuits.

  • Connect the probe ground only to the correct circuit reference point
  • Use the shortest practical ground connection for high-frequency measurements
  • Long ground leads can introduce inductance, ringing and waveform distortion
  • Keep the probe cable away from strong electromagnetic interference where possible
Grounding Warning: On many mains-powered bench oscilloscopes, the BNC outer shell and probe ground clip are connected to protective earth.

Never attach the probe ground clip to an unknown live potential. Incorrect grounding can create a short circuit and may cause equipment damage, electric shock or serious injury.

Ideal For

  • Digital oscilloscope measurements
  • Electronics repair and PCB troubleshooting
  • Microcontroller and Arduino projects
  • PWM signal testing
  • Power-supply diagnostics
  • Audio circuit measurements
  • Sensor and control-signal testing
  • Electronic circuit development
  • Engineering laboratories
  • Technical education and training
  • Workshop diagnostics
  • General waveform analysis

What's Included

  • 1 × ZOYI P2060 60MHz Oscilloscope Probe
  • 1 × Removable Spring Hook Tip
  • 1 × Ground Lead with Alligator Clip
  • 1 × Probe Compensation Adjustment Tool
  • Colour Identification Rings / Markers
  • Probe Tip / Protection Accessories
Please note: Small probe accessories and colour-ring quantities may vary slightly between production batches. Please refer to the listing photographs for the exact accessories supplied.

Technical Specifications

Brand ZOYI
Model P2060
Type Passive Oscilloscope Voltage Probe
Maximum Bandwidth 60MHz
Attenuation Ratio 1X / 10X Switchable
Rise Time Approx. 5.8ns
Input Resistance 1MΩ / 10MΩ ±2%
Input Capacitance — 10X Approx. 14–18pF
Probe Compensation Adjustable
Maximum Input — 1X 150V RMS CAT II
Maximum Input — 10X 300V RMS CAT II
Safety Standard IEC 61010-031
Connector Male BNC
Recommended Scope Input 1MΩ BNC Input
Cable Length Approx. 110 ±2cm
Probe Weight Approx. 55g
Operating Temperature Approx. -10°C to +55°C
Operating Altitude Up to Approx. 3000m

Important Safety Information

Always inspect the probe tip, cable, BNC connector and ground lead for damage before use.

Match the physical 1X / 10X probe setting with the attenuation setting selected on the oscilloscope.

Never exceed the input voltage rating marked on the probe or the maximum input voltage of the connected oscilloscope.

The maximum safe voltage of the complete test setup is determined by its lowest-rated component.

Remember that the probe ground lead may be connected to protective earth through a mains-powered oscilloscope.

Do not connect the ground clip to a live mains conductor or other unknown electrical potential.

Returns & Warranty

  • 🔁 30-Day Returns: Returns accepted in accordance with the eBay listing and applicable UK consumer rights.
  • 🛡️ UK Warranty Support: UK warranty and after-sales support for your ZOYI product.
  • 📦 Return Contents: Please return the probe with its supplied accessories and original packaging where possible.
  • 💬 UK Support: Contact us through eBay if you require product, compatibility or technical assistance.

Fast UK Shipping

📦 Dispatched from UK stock. Orders are securely packaged for transit. UK and international delivery options are shown at checkout. Tracking is provided where applicable.