Tested using AVO VCM MkIII
Overall Test Result: Working (A bit on the low side but still usable)
Equivalent to:
12AU7 B329 CV491 E2163 E812CC
|
Manufacturers Stated Measurements:
A1
Ia (mA) = 10.5
Gm (mA/V) = 2.2
A2
Ia (mA) = 10.5
Gm (mA/V) = 2.2
Actual tested measurements:
A1
Ia (mA) = 6.6
Gm (mA/V) = 1.5
A2
Ia (mA) = 7.5
Gm (mA/V) = 1.6
Comments about this valve(s): Unboxed
A full characteristics check has been performed by me using an AVO VCM MkIII (Valve Characteristics Meter - Calibrated 2025) to detect for "Shorts", "Leakage" "Gas" etc in a cold/hot state, as well as a Visual inspection to provide you peace of mind and a general indication of "Goodness"
Vintage Electrical Parts are NOT Returnable for obvious reasons, However, If there is an issue with your particular order please message me so we can work towards a solution - Thank You