Waldent Dental Lead Apron & Thyroid Shield BARC Approved 0.34mmPb X-Ray Guard
 Waldent BARC Certified Radiation Protection
Dental Lead Apron &
Thyroid Shield Collar
BARC Approved | 0.25 mmPb Apron | 0.58 mmPb Thyroid Collar | Absorbs 90–95% Scattered Radiation
Clinically certified radiation protection — lightweight, comfortable, and built for daily dental use.
DHL / FedEx / Aramex
Worldwide shipping
Authentic Waldent
About the Waldent Lead Apron & Thyroid Shield

The Waldent Lead Apron & Thyroid Shield Collar is a BARC-certified radiation protection system designed for use during dental and medical X-ray imaging procedures. Constructed of a durable thin rubber exterior with an internal lead layer, the apron absorbs 90–95% of scattered radiation, significantly reducing exposure to vital organs including the chest, abdomen, and pelvis.

The companion Thyroid Shield Collar is specifically engineered to protect the thyroid gland — the most radiation-sensitive structure in the neck — during dental imaging. Together, the set provides complete upper-body radiation protection with the comfort and practicality required for busy dental environments.

BARC certification
BARC Certified Certificate Available on Request Tested at 100 KVp Siemens Polydoros-LX Tested
At-a-glance specifications
0.25mm
Lead equivalency — apron
0.58mm
Lead equivalency — collar
90–95%
Scattered radiation absorbed
2.7kg
Apron weight
Key features
Ergonomic Comfort
Weight adjuster and flexible back design shifts weight to the hips, reducing shoulder strain during extended procedures.
Dual Radiation Protection
0.25 mmPb apron + 0.58 mmPb thyroid collar for complete upper-body and thyroid gland protection.
Lightweight Design
At just 2.7 kg, the apron is engineered to minimise fatigue for clinicians wearing protection throughout the day.
BARC Certified
Tested and certified by the Board of Atomic Research Centres — certificate available upon request.
Full feature highlights
Weight adjuster & flexible back — distributes weight comfortably to the hips, reducing shoulder load during long procedures
Velcro straps — quick and secure fastening for easy donning and doffing between patients
Reinforced belt pocket — spacious, strong, and durable for carrying instruments or accessories during procedures
Concealed shoulder pads — built-in padding for added comfort and durability without visible bulk
Soft fabric exterior — gentle against skin and easy to clean between clinical sessions
Full coverage dimensions — 98 cm length from shoulder, 60 cm breadth for comprehensive body coverage
Absorbs 90–95% of scattered radiation — reliable protection for patients and clinical staff during all dental X-ray procedures
Thyroid collar dedicated design — purpose-built to shield the thyroid gland, the most radiosensitive structure in the neck
Product comparison — Apron vs Thyroid Collar
Lead Apron
Lead equivalency0.25 mmPb
Weight2.7 kg
Length98 cm
Width60 cm
CoversChest, abdomen, pelvis
Tested at100 KVp
Thyroid Shield Collar
Lead equivalency0.58 mmPb
Weight554 g
StyleCollar / wrap
CoversThyroid gland
Tested at100 KVp
CertificationBARC Approved
Ideal for
Dental clinics Dental schools Radiology departments Dental assistants & nurses Medical imaging centres
Directions for use
1
Wear the lead apron
Place the lead apron over your shoulders, ensuring it covers the chest, abdomen, and pelvic areas completely. Fasten the Velcro straps securely at the sides.
2
Position the thyroid shield collar
Wrap the thyroid collar around the neck and position it to fully cover the thyroid area. Ensure it sits snugly without restricting breathing or movement.
3
Adjust for comfort & fit
Use the weight adjuster to shift load to the hips for reduced shoulder strain. Ensure both the apron and collar fit comfortably and securely without restricting movement or posture.
4
Verify coverage before X-ray
Confirm that the lead apron provides adequate coverage of the torso and that the thyroid collar fully protects the thyroid gland before initiating X-ray exposure.
5
Remove & store after use
After the procedure, carefully remove the apron and collar. Hang the apron on the included hanger — never fold it, as folding can crack the internal lead layer. Store in a clean, dry location away from direct sunlight.
Technical specifications
Waldent Lead Apron
Brand
Waldent
Lead equivalency
0.25 mmPb at 100 KVp
Weight
2.7 kg
Length
98 cm (from shoulder)
Width
60 cm
Closure
Velcro straps
Radiation absorbed
90–95% of scattered radiation
Test equipment
Siemens Polydoros-LX (max 150 KV, max 800 mA)
Certification
BARC Certified
Waldent Thyroid Shield Collar
Lead equivalency
0.58 mmPb at 100 KVp
Weight
554 g
Protection area
Thyroid gland
Test equipment
Siemens Polydoros-LX (max 150 KV, max 800 mA)
Certification
BARC Certified
Package includes
Lead Apron1× Waldent dental lead apron
Apron Hanger1× dedicated storage hanger
Thyroid Shield Collar1× Waldent thyroid shield collar
Shipping & import
US Shipping Policy
DDP — Delivered Duty Paid
No surprise import charges for US buyers
All US orders are shipped under DDP (Delivered Duty Paid) terms.
Import duties prepaid by seller
All applicable import duties and taxes for US shipments are prepaid before dispatch.
No additional charges at delivery
US buyers will not be asked to pay extra customs duties or import fees upon delivery.
Smooth & hassle-free delivery
What you see at checkout is the final amount payable for most US orders.
For United States orders only. Express delivery in 10–15 days via DHL / FedEx / Aramex. International shipping available — local customs duties may apply for non-US orders.
Regulatory notice
FDA disclaimer: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not purchase unless you are an authorized buyer. If the item is subject to FDA regulation, your status as an authorized purchaser will be verified before shipment.