Features

Width only 32mm
Compliance to EN50155 and EN45545-2 railway standard
DC output adjustable ( 10%)
2:1 wide input range
150% peak load capability
Protections: Short circuit / Overload / Over voltage /Input reverse polarity / Input under voltage protection
4KVdc I/O isolation(Reinforced isolation)
Can be installed on DIN rail TS-35/7.5 or 15
-40~+70°C wide working temperature
Cooling by free air convection
3 years warranty

General Specification

Over current protectionNormally works within 150% rated output power for more than 3 seconds and then constant current protection 105~135% rated output power with auto-recovery
Over voltage protection

12V:13.8~16.2V ; 15V:17.25~20.25V ; 24V:28.8~32.4V;

Protection mode: Shut down o/p voltage, re-power on to recover

REVERSE POLARITYBy internal MOSFET, no damage, recovers automatically after fault condition removed
Withstand voltageI/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
Working temperature-40~+70°C (Refer to ""Derating Curve"")
Safety standardsIEC 62368-1 (LVD),EAC TP TC 004 approved, Design refer to UL508
EMC standardsWith external components Compliance to EN55032 Class B;EN61000-3-,3,EN61000-4-2,3,4,5,6,8
Dimension (LxWxH)(mm)32 x 125.2 x 102 mm