Tips:

Affected by Epidemic Recently, due to shortage of workers, the online update information and deliverey will have some delay. Please don't worry, just contact me, I will keep tracking and update.


Features

1.Knob comes with start and stop function

2.Slow start and slow stop time can be set

3.Limit the upper and lower limit of the speed

4.Frequency 1-100KHZ can be set

5.Use digital encoder knob, stable and durable, high precision and better consistency

6.Parameters can be set for power-down storage


Product parameter

Input voltage: DC6-60V (the specific voltage is equal to the rated voltage of the motor)

Output voltage: linear under load

Output current: 0-30A

continuous current: within 20A

Speed regulation type: current regulation

speed regulation method: encoder knob 360 degrees

Speed adjustment range: 0-100% can be set

frequency: 1-100KHZ can be set

Slow start and slow stop: Can be set

Digital speed display: 0-100 percentage meter

Wiring type: Barrier terminal block

Support motor: brushed motor

Module size: length * width * height 96mm*61mm*34mm

product net weight: 105g

Panel opening: length * width 92mm*56mm

installation method: embedded


Package Includes:

1 x Speed Controller


Digital encoder knob operation

Short press-switch motor start and stop

Long press-enter the setting interface

Clockwise-increase


Counterclockwise-Decrease

Enter the setting interface short press: switch function 1 function 2 function 3 function 4 function 5 function 6 long press to save and exit

Enter the setting interface to rotate: turn left to decrease the value, turn right to increase the value

low start time setting Function 1: 000-100 The slow start to 100% speed time is adjustable between 0-10 seconds. The default is 1 second.

Slow stop time setting Function 2: 000-100 The slow stop time is adjustable between 0-10 seconds. The default is 1 second.

Speed lower limit setting function 3: 000-080 The minimum speed is adjustable between 0-80% and less than the maximum speed setting value. The default is 0.

Speed limit setting function 4: 000-100 The maximum speed is adjustable between 0-100% and is greater than the minimum speed setting value. The default is 100%.

Acceleration and deceleration value setting Function 5: 001 002 005 010 015 020 025 The speed changes correspondingly for each revolution 1%, 2%, 5%, 10%, 15%, 20%, 25%.

Frequency setting function 6: adjustable between 1-100KHZ, default 15KHZ


Notice:

The input voltage must be divided into positive and negative, not 220V

The input voltage should be equal to the rated voltage of the motor within 6-60V

Such as the motor 12V input 12V, the motor 36V input 36V