‧Universal AC input / Full range
‧Withstand 300VAC surge input for 5 second
‧No load power consumption<0.3W
‧Miniature size and 1U low profile
‧High operating temperature up to 70℃
‧Protections: Short
circuit / Overload / Over voltage
‧Cooling by free air convection
‧Compliance to IEC/EN 60335-1(PD3) and IEC/EN61558-1, -2-16 for household appliances
‧Operating altitude up to 5000 meters (Note.7)
‧Withstand 5G vibration test
‧High efficiency, long life and high reliability
‧LED indicator for power on
‧Over voltage category Ⅲ
‧100% full load burn-in test
‧3 years warranty
‧Industrial automation machinery
‧Industrial control system
‧Mechanical and electrical equipment
‧Electronic instruments, equipment or apparatus
‧Household appliances
LRS-100 series is a 100W single-output enclosed type power supply with 30mm of low profile design.
Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 3.3V, 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 91%, the design of metallic mesh case enhances the heat dissipation of LRS-100 that the whole series operates from -30℃ through 70℃ under air convection without a fan.
Delivering an extremely low no load power consumption (less than 0.3W).
It allows the end system to easily meet the worldwide energy requirement.
LRS-100 has the complete protection functions and 5G anti- vibration capability.
It is complied with the international safety regulations such as TUV EN62368-1, EN 60335 - 1 , EN 61558 - 1 / - 2 - 16 , UL 62368 - 1 and GB 4943 .
LRS- 100 series serves as a high price- to- performance power supply solution for various industrial applications.
|
MODEL |
LRS-100-3.3 |
LRS-100-5 |
LRS-100-12 |
LRS-100-15 |
LRS-100-24 |
LRS-100-36 |
LRS-100-48 |
|
|
OUTPUT |
DC
VOLTAGE |
3.3V |
5V |
12V |
15V |
24V |
36V |
48V |
|
RATED CURRENT |
20A |
18A |
8.5A |
7A |
4.5A |
2.8A |
2.3A |
|
|
CURRENT RANGE |
0 ~ 20A |
0 ~ 18A |
0 ~ 8.5A |
0 ~ 7A |
0 ~ 4.5A |
0 ~ 2.8A |
0 ~ 2.3A |
|
|
RATED POWER |
66W |
90W |
102W |
105W |
108W |
100.8W |
110.4W |
|
|
RIPPLE & NOISE
(max.) Note.2 |
100mVp-p |
100mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
|
|
VOLTAGE ADJ. RANGE |
2.97 ~ 3.6V |
4.5 ~ 5.5V |
10.2 ~ 13.8V |
13.5 ~ 18V |
21.6 ~ 28.8V |
32.4 ~ 39.6V |
43.2 ~ 52.8V |
|
|
VOLTAGE TOLERANCE Note.3 |
±3.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
|
LINE REGULATION Note.4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
|
LOAD REGULATION Note.5 |
±2.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
|
SETUP, RISE TIME |
500ms, 30ms/230VAC 500ms,30ms/115VAC at full load |
|||||||
|
HOLD UP TIME (Typ.) |
55ms/230VAC 10ms/115VAC at full load |
|||||||
|
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC 120
~ 373VDC (Withstand 300VAC surge for 5sec. Without
damage) |
||||||
|
FREQUENCY RANGE |
47 ~ 63Hz |
|||||||
|
EFFICIENCY (Typ.) |
84.5% |
86% |
88% |
88.5% |
90% |
90.5% |
91% |
|
|
AC CURRENT (Typ.) |
1.9A/115VAC 1.2A/230VAC |
|||||||
|
INRUSH CURRENT (Typ.) |
COLD START 50A/230VAC |
|||||||
|
LEAKAGE CURRENT |
<0.75mA / 240VAC |
|||||||
|
PROTECTION |
OVER LOAD |
110 ~ 150% rated
output power |
||||||
|
Protection type : Hiccup
mode, recovers automatically after fault condition is removed |
||||||||
|
OVER VOLTAGE |
3.8 ~ 4.45V |
5.75 ~ 6.75V |
13.8 ~ 16.2V |
18.75 ~ 21.75V |
28.8 ~ 33.6V |
41.4 ~ 48.6V |
55.2 ~ 64.8V |
|
|
Protection type : Shut down o/p voltage, re-power on to recover |
||||||||
|
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70℃ (Refer to "Derating Curve") |
||||||
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|||||||
|
STORAGE
TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH non-condensing |
|||||||
|
TEMP. COEFFICIENT |
±0.03%/℃ (0
~ 50℃) |
|||||||
|
VIBRATION |
10 ~ 500Hz, 5G 10min./1cycle, 60min.
each along X, Y, Z axes |
|||||||
|
OVER VOLTAGE CATEGORY |
Ⅲ; Compliance to EN61558, EN50178,
EN60664-1, EN62477-1; altitude
up to 2000 meters |
|||||||
|
SAFETY & EMC (Note 8) |
SAFETY STANDARDS |
UL 62368-1,
TUV EN62368-1,
EN60335-1, EN61558-1/-2-16,CCC GB4943.1,
BSMI CNS14336-1, EAC TP TC 004, AS/NZS62368.1(by CB),KC K60950-1(for LRS-100-12/24 only) approved |
||||||
|
WITHSTAND VOLTAGE |
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC |
|||||||
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG,
O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
|||||||
|
EMC EMISSION |
Compliance
to EN55032 (CISPR32) Class B, EN55014,
EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020, KC KN32,KN35(for LRS-100-12/24 only) |
|||||||
|
EMC IMMUNITY |
Compliance
to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2
(EN50082-2), heavy
industry level,
criteria A, EAC
TP TC 020, KC KN32,KN35(for LRS-100-12/24 only) |
|||||||
|
OTHERS |
MTBF |
720.6K hrs min. MIL-HDBK-217F (25℃) |
||||||
|
DIMENSION |
129*97*30mm (L*W*H) |
|||||||
|
PACKING |
0.34Kg ; 40pcs/14.6Kg/0.92CUFT |
|||||||
|
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC
input, rated load and
25℃ of
ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 7. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft). 8. The
power supply is considered a component which will be installed into a final equipment. All the EMC tests are been
executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. |
|||||||