This product is used Quantitative determination of human whole blood (venous blood and capillary blood) of total cholesterol(TC),high-density lipoproteincholesterol(HDL),triglyceride(TG) used only for daily self-monitoring, and its test results can not be used as a basis for clinical diagnosis, screening and instruction of drugs.
Product Description:
✅ 5 RESULTS FROM ONE TEST – Measures total cholesterol (TC), triglycerides (TG), and HDL cholesterol, while providing calculated LDL cholesterol and the TC/HDL ratio for routine at-home lipid monitoring.
✅ PROFESSIONAL GRADE FOR HOME USE – Our device provides the closest and most accurate Cholesterol breakdown and analysis to a lab test from home! This lipid test kit will give you reliable consistent results that you can depend on.
✅ 30-STRIP VALUE BUNDLE – This virtual bundle combines the PFS-30A meter kit with 10 test strips and a 20-strip refill pack, providing up to 30 tests in total. The meter kit also includes a lancing device, single-use lancets, code card, blood collection tube,and carrying case.
✅ RESULTS IN ABOUT 2 MINUTES – Uses a 40 μL whole-blood sample and displays results in approximately 2 minutes. The large screen makes readings clear and easy to review.
✅ TWO DISPLAY UNITS – The blood lipid meter has two display units: mg/dl and mmol/L, which you can switch between at will.
✅ FOR ROUTINE TRACKING – Stores up to 300 previous results, making it easier to review readings and monitor lipid trends over time as part of your regular wellness routine.
✅ IMPORTANT USE INFORMATION – Use only with compatible PFS 30 blood lipid test strips and the matching code card. Follow the instructions for use, use strips before their expiration date.
✅ SETUP GUIDANCE AND SUPPORT – Easy-to-follow instructions and video tutorials help with setup and routine use, while product support is available for product-related questions.



Q&A:
Why does the test result show HI/LO?
Test results exceed the upper/lower instrument test limits due to incorrect operation
Solution:
1. Insert the correct code card and make sure the code matches the test strip code
2. Ensure that enough sample (35uL~40uL) is added to the test
3. Use alcohol to sterilize during sampling (avoid iodine)
4. Please dry your fingertips with alcohol when taking the sample
• Test bereich:
① Tc: 2.59 mmol/l-12.93 mmol/l
(100mg/dL-500mg/dl)
② Tg: 0.51 mmol/l-7.34 mmol/l
(45mg/dL-650 mg/dl)
③ Hdl: 0.39 mmol/l-2.59 mmol/l
(15mg/dL-100mg/dl)
④ Ldl = TC-HDL-TG/2.2 mmol/l
(TC-HDL-TG/5mg/dl)
• Type of samples: Capillaries Total blood test, venous blood
• Dosing samples: approx. 35-40 μl
• Storage capacity: 300 groups
• Test time:<2 minutes
• Analyzer live: 5 years
• Test strip expiration date:
Unopened test strip expiration date (18 months)
Expiry date of test strips after opening (3 months,10 test strips/bottle) Once opened, the test strips must be sealed and stored properly,Please tighten the cap.
Precautions during testing:
1. Sufficient blood sample should be drawn in one go. If the blood sample is insufficient, do not add a second sample to increase the blood volume; the test strip must be replaced and the test repeated. (The blood volume must reach the black line on the collection tube.)
2. Check the blood collection site for sufficient blood flow, clean with hand cream, and do not use iodine-containing disinfectants. Increase blood flow by warming and rubbing the fingers.
3. If blood flow is insufficient, do not squeeze the finger excessively to draw blood; a second blood sample must be drawn. Excessive squeezing can cause excessive tissue fluid to mix with the blood sample, resulting in significant deviations in the test results.
4. Before inserting the strip, check that it is normal and that the test well membrane is free from severe misalignment, stains, etc.
5. Ensure that the blood drop symbol flashes before adding the sample. Otherwise, the test results will be inaccurate.
6. After the test begins, do not operate the instrument buttons, move the instrument or the test strip until the instrument displays the test results.
Purchase Notes:
1. Errors in Blood Lipid Testing Instruments:
Both home-use testing instruments and hospital test results will have a certain degree of error. The error range is within national standards, and if the test is performed according to the normal instrument operating procedures, the difference in results will be minimal.
2. Reasons for Excessive Errors in Test Results:
A: Improper operation. Strict adherence to the standard operating procedures is required.
B: Blood lipid levels change dynamically at different times. Instrument data must be compared with data from a hospital test report taken on the same day for the data to be valid.
Product List:(Meter + 30 lipid test strips)
① Analyzer*1
② Lancet pen*1
③ Test strip*30
④ Lancet*30
⑤ Blood collection tube*30
⑥ Storage bag *1
⑦ English User Manual *1