DT-156 Dual Technology Features Automatic Selection of Magnetic Induction or Eddy Current Measurement Techniques
Non-magnetic coatings (e.g. paint, zinc) on steel
Insulating coatings (e.g. paint) on no-ferrous metals
No-ferrous metals coatings on insulating substrates
Menu operation system
Two working modes: DIRECT and GROUP mode
One point calibration, two points calibration and basic calibration easily
Delete single readings and all group readings easily
Low battery, error indication

 

Features DT-156
Non-magnetic coatings (e.g. paint, zinc) on steel *
Insulating coatings (e.g. paint) on no-ferrous metals *
No-ferrous metals coatings on insulating substrates *
Menu operation system *
Two measuring modes: CONTINUE and SINGLE mode *
Two working modes: DIRECT and GROUP mode *
Statistic Display: AVG, MAX, MIN, NO., S.DEV *
One point calibration, two points calibration and basic calibration easily *
Memory for 400 readings (80 DIRECT and 320 GROUP readings) *
Delete single readings and all group readings easily *
High alarm and Low alarm for all working modes *
Low battery, error indication *
USB interface for PC software *

 

Size (H x W x D): 113.5mm x 54mm x 27mm
Weight: 110g

 

Specifications DT-156
Sensor probe F N
Working principle magnetic induction Eddy current principle
Measuring range 0~1250um 0~1250um
Guaranteed tolerance (of reading) (+/- 3%+1)um (+/- 3%+1.5)um
Repeatability (+/- 1%+1)um (+/- 1%+1)um
Low range Precision 0.1um 0.1um
Minimum curvature radius 1.5mm 3mm
Diameter of Minimum area 7mm 5mm
Basic critical thickness 0.5mm 0.3mm