Ultrasonic Fixed Flowmeter Flow Meter TS-2 Transducer DN25-100mm 
 


Standard Packing:
This TUF-2000F Ultrasonic Flowmeter comes with
TS-2 Transducer : DN25-100mm  , temperature: -30~90  size: 42*25*32mm


Feature: 
▲High Accuracy : 1%
▲Wide measuring range :Several types transducer for selection, pipe size from Dn15mm to Dn6000mm
▲High Reliability :Adopt low voltage, multi-pulse technology to improve accuracy, operation life and reliability.
▲Strong Anti-interference  :Dual-balance signal differential receiver/driver circuit to avoid interference of converter, TV tower, high voltage line etc.
Powerful Recording Function
▲Automatically record the following data:
1. The totalizer data of the last 512 days/128 months/10 years
2. The time and corresponding flow rate of the last 6 4 times of power on and off events
3. The working status of the last 32 days
▲Support Heat Measurement : Connect the temperature transducer ,can finish the heat/energy measurement



Technical Specifications
▲Principle: transit-time ultrasonic flowmeter

▲Accuracy:  Flow: over 1%-2%(battery-powered supply over ±2% ),Heat: over ±2%,Repeatability: over 0.2%

▲Operation:Support 4 keyboards magnetic bar/simulation keyboard software

▲Signal Output:
*1 way 4~ 20mA output, electric resistance 0~ 1K,accuracy0. 1%
*1 way OCT pulse output( Pulse width 6 ~ 1 0 0 0 ms,default is 2 0 0 ms)
*1 way Relay output

▲Signal Input
*3 way 4~ 20mA input, accuracy 0. 1%,acquisition signal such as temperature, press and liquid level
*Connect the temperature transducer Pt100, can finish the heat/energy measurement

▲Data interface:Insulate RS485 serial interface, upgrade the flew meter software by computer, support the MODBUS, METER-BUS etc.

▲Other Function:
*Automatically remember the previous flew/energy data of 512 days,  128 months and 10 years
*Automatically remember the previous flew/energy data of 512 days working condition and check it
*Automatically remember the previous 32 times power on/off time and flow rate

▲Special Cable:Twisted-pair cable, generally, the length under 50 meters;Select the RS485 communication. The transmission distance can over 1000m.

▲Pipe Condition:
*Pipe Material:Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed.
*Pipe Diameter:25-100mm
*Straight length pipe:Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump.

▲Measuring Medium:
*Type of Liquid:Water (hot water, chilled water, city water, sea water, waste water, etc.);  Sewage with small particle content; Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);  Chemicals (alcohol, acids, etc.); Plant effluent; Beverage, liquid food; Ultra-pure liquids; Solvents and other liquids
*Temperature:Standard Transducer: -30--90℃; High-temperature transducer: -30--140℃
*Turbidity :No more than 10000ppm and less bubble
*Flow rate:0--±7 m/s

▲Working Environment:
*Temperature: Main Unit: -20--60℃, Flow transducer: -40--160℃;,Temperature transducer: according to the customer’s demands.
*Humidity : Main Unit: 85% RH; Flow Transducer: Ip67

▲Power Supply:DC  24V or AC  85-264V

▲Power Consumption:1.5W