Digital Earth Resistance Online Detector On-Line Monitoring Resistance Tester 

 

 

Overview

Earth Resistance Online Detector is high-tech product that our company has devoted to "grounding resistance detection technology research" for more than ten years, Using precision 3-wire or simple 2-wire measurement method to test the grounding resistance. Adopt average value rectification method to test grounding voltage, online detection, real-time monitoring. User can select RS232 or RS485 communication, according the protocol MODBUS to secondary development, build network, realize remote multipoint online monitoring etc.

Earth Resistance Online Detector displayed by super large LCD, very clear and obvious. The alarm critical value can be set via the button, and with the sound and light alarm indication. Ensure the high accuracy, high stability and high reliability of real-time online monitoring of grounding resistance value in various place.

Earth Resistance Online Detector Tester suitable for transmission line tower grounding, underground mine equipment grounding , weather lightning protection grounding, petrochemical grounding ,communication base station grounding, power substation grounding , railway grounding , building warehouse grounding , electrical equipment grounding, etc.

 

Specification

Measurement Range & Accurancy

Measurement Function

Range

Accuracy

Resolution

Earth Resistance

0.01Ω20Ω

±2%rdg±3dgt (auxiliary earth resistance 100Ω±5%Voltage to earth10V)

0.01Ω

0.1Ω200Ω

±2%rdg±3dgt (auxiliary earth resistance 100Ω±5%Voltage to earth10V)

0.1Ω

2000Ω

±2%rdg±3dgt (auxiliary earth resistance 100Ω±5%Voltage to earth10V)

Earth Voltage

0600V AC

±2%rdg±3dgt

1V

(Note: 23±5below 75%rh)

 

Technical Parameter


Function

Description

Measure Mode

Precise 3-wire measurement ,simple 2-wire measurement

Measure Method

Ground resistancerated current change-pole methodmeasured current11mA Max128Hz

voltage to ground average value ectification method.

Power Supply

Standard12V±1VDC400mA Maxprovided externally

Weight

Detector:380g

Dimension

130mm×90mm×54mm

LCD Size

47mm×28.5mm

Measurement Time

Voltage to groundabout 2 times/second ; ground resistance : about 30 seconds/time

Measurement Rate

Over 10000  times

Monitoring Interval  Time

Setting range of automatic monitoring interval time :1-999 h

Instrument Interface

Pluggable  terminal blocks: 9 pin connector

Communication  Method

RS485 or GPRS

Data Storage

99 groupsflash display “99”  symbol indicate storage is full

Data Access

Data read function :“READ” symbol display

Overflow Display

Exceed measurement range overflow function :”OL” symbol display

Alarm

Audible and visible alarm

Power Supply Voltage

When power supply voltage decreases to about 10V , power supply low symbol will display, and remind to replace  the power.

Overload Protection

Measurement ground resistance: E-P, E-C between each interfaces AC 280V/3 seconds

Electromagnetism

IEC61010-4-3,Wireless frequency electromagnetic field≤1V / m

Line Voltage

Measuring the voltage to ground: Below AC 600V

Accessories

Detector: 1PCS; GPRS Communication module+external antenna1setoptinal),9P terminal block