ORIGINAL & Brand New CiTiceL4OXV AAY80-390 Oxygen Sensor 4OXV 40XV 40X-V 1Pcs
Features: - To space out the rear oxygen sensor from the path of exhaust gases,etc. - Fast response,corrosion resistant,and lower consumption. - Also works well in coal mining,petrochemical and medical industries. - Easy to install,no modification needed.
Specifications: Condition:100% Brand new Measurement Range:1-25% vol. O2 Maximum Overload:30% vol. O2 Output Signal:0.10±0.02 mA in Air Response Time (T90):<15 Seconds Zero Current (Offset):<0.6% vol. O2 Operating Temperature Range :-20°C to +50°C (up to 3-month-continuous across RH range) Recommended Storage Temp :0°C to 20°C Thermal Transient :<23.5% vol. O2(Temp. plunge +22°C to -20°C) Operating Pressure Range :Atmospheric ± 20% Pressure Coefficient :<0.02% signal/mbar Pressure Transient :<200% signal change (60 cm H2O step change) Relative Humidity Range :(at 0°C to 20°C) Continuous :5 to 95%RH non-condensing
Note: - Different batches have different package designs and MFG,please refer to the real item. - Prohibit using electric iron to solder the pin of this sensor,please use the pins along with the package. - Prohibit using exothermic,volatile and corrosive glue to fill the gap.