Note: After unpacking the test strips, please keep the rest of them sealed so that the test strips will not be affected by moisture and affect the test results!!!!

 

 

This product is used Quantitative determination of human whole blood (venous blood and capillary blood) of total cholesterol(TC),high-density lipoproteincholesterol(HDL),triglyceride(TG) used only for daily self-monitoring, and its test results can not be used as a basis for clinical diagnosis, screening and instruction of drugs.

 

Product Description:
 
 

The dangers of dyslipidemia:
01、caused by cardiovascular and cerebrovascular diseases and its mortality rate has exceeded the cancer ranked first.
02、one of the important factors leading to atherosclerosis.
03、is an independent risk factor for coronary heart disease and ischemic stroke.
04、there is no obvious symptoms, but once the onset of the disease may cause injuries 04 disability or death.
05、Complications such as diabetes, hypertension, liver disease, etc.
06、Triggering systemic diseases.

• Test bereich:

① Tc: 2.59 mmol/l-12.93 mmol/l

(100mg/dL-500mg/dl)

② Tg: 0.51 mmol/l-7.34 mmol/l

(45mg/dL-650 mg/dl)

③ Hdl: 0.39 mmol/l-2.59 mmol/l

(15mg/dL-100mg/dl)

④ Ldl = TC-HDL-TG/2.2 mmol/l

(TC-HDL-TG/5mg/dl)

• Type of samples: Capillaries Total blood test, venous blood

• Dosing samples: approx. 35-40 μl

• Storage capacity: 300 groups

• Test time:<2 minutes

• Analyzer live: 5 years

 
Precautions during testing:
1. Sufficient blood sample should be drawn in one go. If the blood sample is insufficient, do not add a second sample to increase the blood volume; the test strip must be replaced and the test repeated. (The blood volume must reach the black line on the collection tube.)
2. Check the blood collection site for sufficient blood flow, clean with hand cream, and do not use iodine-containing disinfectants. Increase blood flow by warming and rubbing the fingers.
3. If blood flow is insufficient, do not squeeze the finger excessively to draw blood; a second blood sample must be drawn. Excessive squeezing can cause excessive tissue fluid to mix with the blood sample, resulting in significant deviations in the test results.
4. Before inserting the strip, check that it is normal and that the test well membrane is free from severe misalignment, stains, etc.
5. Ensure that the blood drop symbol flashes before adding the sample. Otherwise, the test results will be inaccurate.
6. After the test begins, do not operate the instrument buttons, move the instrument or the test strip until the instrument displays the test results.

 

 

Color: Lipid meter + 10 test strips

① Analyzer*1

② lancet pen*1

③ Test strip*10

④ lancet*10

⑤ Blood collection tube*10

⑥ Storage bag *1

⑦ manual *1

 