- Suitable for industrial, mobile, cooling and lubricating applications
- High protection rating for the requirements of harsh industrial environments
- Wide operating temperature range
- Safe detection due to large sensing range and low sensor tolerances
- Reduced inventory due to wide range of applications
Product characteristics
>th >Dimensions [mm]
| Electrical design | PNP |
|---|
| Output function | normally open |
|---|
| Sensing range [mm] | 4 |
|---|
| Housing | |
|---|
| M12 x 1 / L = 60 |
Application
| System | gold-plated contacts; Increased sensing range |
|---|
| Application | Suitable for industrial, mobile, cooling and lubricating applications; Industrial applications |
|---|
Electrical data
| Operating voltage [V] | 10...30 DC |
|---|
| Current consumption [mA] | < 10 |
|---|
| Protection class | III |
|---|
| Reverse polarity protection | yes |
|---|
Outputs
| Electrical design | PNP |
|---|
| Output function | normally open |
|---|
| Max. voltage drop switching output DC [V] | 2.5 |
|---|
| Permanent current rating of switching output DC [mA] | 100 |
|---|
| Switching frequency DC [Hz] | 700 |
|---|
| Short-circuit protection | yes |
|---|
| Overload protection | yes |
|---|
Monitoring range
| Sensing range [mm] | 4 |
|---|
| Real sensing range Sr [mm] | 4 ± 10 >#/td### |
|---|
| Operating distance [mm] | 0...3.24 |
|---|
| Increased sensing range | yes |
|---|
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.4 / copper: 0.3 |
|---|
| Hysteresis [% of Sr] | 3...15 |
|---|
| Switch-point drift [% of Sr] | -10...10 |
|---|
Operating conditions
| Ambient temperature [°C] | -40...85 |
|---|
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K |
|---|
Tests / approvals
| EMC | | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | | EN 61000-4-3 HF radiated | 10 V/m | | EN 61000-4-4 Burst | 2 kV | | EN 61000-4-6 HF conducted | 10 V | | EN 55011 | class B |
|
|---|
| Vibration resistance | | EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
|
|---|
| Shock resistance | | EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
|
|---|
| Continuous shock resistance | | EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
|
|---|
| Fast temperature changes | | EN 60068-2-14 Na | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
|
|---|
| Salt spray test | | EN 60068-2-52 Kb | severity level 5 (4 test cycles) |
|
|---|
| MTTF [years] | 1642 |
|---|
| Embedded software included | yes |
|---|
| UL approval | |
|---|
Mechanical data
>th >Mounting
| Weight [g] | 27.7 |
|---|
| Housing | |
|---|
| flush mountable |
| Dimensions [mm] | M12 x 1 / L = 60 |
|---|
| Thread designation | M12 x 1 |
|---|
| Material | brass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated |
|---|
Displays / operating elements
| Display | | Switching status | 4 x LED, yellow |
|
|---|
Accessories
Remarks
Electrical connection - plug
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
|---|
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — IFS240-00 — 13.04.2023 —